Owner‘s Manual Crimping Machine CM 25-3.4
Rev.: 2020-06-24
16 / 20
11. Maintenance and Repair
11.1. Maintenance of crimping machine
• The Crimping Machine CM 25-3.4 is maintenance-free.
• Any necessary repairs may only be performed by qualified personnel or certified technicians at the
manufacturer; only original equipment parts from the manufacturer may be used.
• The electronic counter mechanism has an estimated life of about 8 years. A replacement of the battery
is not possible. After such time has passed, the entire counter mechanism needs to be exchanged
(ATTENTION: Loss of data for the permanent counter, number of cycles will not be stored).
11.2. Electronic Counter Mechanism
The Crimping machine CM 25-3.4 has two electronic counting mechanisms. The upper counter mechanism
is a permanent counter, which cannot be set back by the operator. The lower counter can be reset.
The counter should not be used in explosion-proof areas and/ or areas, which are
excluded in standard EN 61010 part 1.
Attention
10.11. Wear monitoring – General information
Every tool, even if used for the purpose intended for, will show signs of wear and tear. When pushing and
holding down the “MODE” button for 8-15 seconds, the information about the current state and numeric
figures of the tool are displayed.
The information is displayed in the following order:
• Serial number (8 consecutive numbers)
• Remaining life in % (remaining utilization capacity)
• Reference value – lowest adjustment value as defined by the manufacturer
• Quantity of crimps performed