4 Bedienung im Normalbetrieb
4 - 3
4.2 Starting normal operation
The following section explains how to start the compressor and
contains essential points for normal operation.
Danger!
There are moving parts inside the compressor cabinet which
can cause serious injuries.
Never operate the compressor with the cabinet open!
Check the following points before starting the compressor:
Was the direction of rotation checked?
Is the main switch on?
Are any existing shut-off valves open?
Step
Operation
Figure / Expl.
1
Turn the switch to the
right to start the
compressor
.
2
Monitor the following
points at regular intervals
during operation:
2a
Operating pressure
The operating pressure
displayed must not
exceed the maximum
permissible value
specified on the type
plate. If this is the case,
switch off the
compressor immediately.
Pressure gauge
2b
Operating temperature
For 1,5 - 2,2 kW
compressors the
operating temperature
may not exceed 180°C,
for 3,7 - 5,5 kW
compressors 240°C and
for 7,5 kW compressors
260°C. The compressor
is automatically shut off if
there is an excess
temperature.
Combistat
Contents
Before starting the
compressor
Start compressor
and monitor in
normal operation