CobraNet.exe

This program developed by Renkus-Heinz is used for the control of Renkus-Heinz’s CobraNet
products.  Through the use of this program, you will be able to select the receivers, transmitters, and
audio channel selections for the Renkus-Heinz CobraNet units.  The following section covers the
operation of the CobraNet.exe program.

Main Screen for CobraNet.exe Program

Unit Information Section

The controlling of the CobraNet device is accomplished by using the unit’s IP address.  To
determine the unit’s IP address, please refer to the CobraNet Discovery section of this manual.

IP Address:

This is where you enter the IP address of the unit you would like to control.  The IP Address
number, for example, should look something like 192.168.1.100.  The IP address of a
particular unit,  could change for a particular unit from day to day.  If the network has other
equipment added to it, the IP address will be reassigned to avoid having two units with the
same IP address.  It’s best to always view the CobraNet Discovery program first in order to
obtain the current IP address for a particular unit.

Name:

In this field you can enter in a custom name for a unit in order to aid in its identification. For
example, ST7.

Location:

In this field, text can be entered to help identify where a particular unit is located.  For
example, Left Cluster Position 1.

Summary of Contents for CobraNet

Page 1: ...NetTM User s Manual 19201 Cook Street Foothill Ranch CA 92610 3501 USA Phone 949 588 9997 Fax 949 588 9514 Email sales renkus heinz com Web www renkus heinz com CobraNetTM is a registered trademark of...

Page 2: ...tions 3 Introduction 4 What is CobraNet 4 System Design 4 CobraNet Hardware 5 Input Output Connections 5 Unit Identification 6 Software 7 CNDisco exe CobraNet Discovery Program 7 CobraNet exe 9 R Cont...

Page 3: ...OPEN CAUTION TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE THE COVER NO USER SERVICE ABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL VORSICHT GEFAHR EINES ELEKTRISCHEN SCHLAGES...

Page 4: ...ngle CAT5 cable Because of the use of CAT5 cabling installation costs can be greatly reduced System Design The basic components required for a CobraNet system are shown in the block diagram below Cobr...

Page 5: ...rogram continues uninterrupted CobraNet Hardware Renkus Heinz offers CobraNet in two different configurations The first configuration is installed inside a self powered loudspeaker capable of acceptin...

Page 6: ...wered loudspeaker Indicators CobraNet Ethernet RJ 45 LEDs On each of the RJ 45 Ethernet connectors are two LEDs If the Primary connector is being used then the LEDs on this connector will show activit...

Page 7: ...rocedure 1 Open the CobraNet Discovery program 2 Under the View menu select Options 3 In the IP Address Range box uncheck the Enable Auto Assignment check box 4 Set the Start IP address for the desire...

Page 8: ...devices located on the CobraNet network Here you will see the MAC address and the IP address that has been assigned to each device By using this window you will now be able to see the IP address for...

Page 9: ...ry section of this manual IP Address This is where you enter the IP address of the unit you would like to control The IP Address number for example should look something like 192 168 1 100 The IP addr...

Page 10: ...unicast bundle or there is no transmitter transmitting on that bundle number For the transmitter after entering your desired bundle number the background color of the box will change If the backgroun...

Page 11: ...o channels are coming from The Speaker Monitor path routs audio from the individual speaker amplifier outputs onto the CobraNet network By using R Control in conjunction with CobraNet you have the abi...

Page 12: ...sired loudspeaker and then select Ch 2 in the CobraNet section and that channel will be transmitted back down the CobraNet network R Control and CobraNet Combiner Box RC CAT5BOX Normally the R Control...

Reviews: