background image

12

CobraNet

TM

 User’s Manual

Exit Button

Exits the program.

R-Control with CobraNet:

When the CobraNet module is installed inside a loudspeaker, you have the ability to monitor each
individual amplifier channel inside the loudspeaker.  This feature allows you to remotely listen to the
audio coming out of each amplifier channel located inside self-powered loudspeakers.  This feature
is not available on the CobraNet Breakout box.

For example, if you would like to listen to the midrange amplifier output, via R-Control you select
the desired loudspeaker and then select Ch 2 in the CobraNet section and that channel will be
transmitted back down the CobraNet network.

R-Control and CobraNet Combiner Box (RC-CAT5BOX):

Normally the R-Control network uses a twisted pair of wires for the network connections.  R-Control
can be sent down the CobraNet CAT5 cable by using the unused pairs of wires on the CAT5 cable.
The R-Control and CobraNet Combiner Box (RC-CAT5BOX) can be used for accomplishing this.
The Combiner connects the twisted pair network to the unused wires on the CAT5 cable.  One
Combiner must be used at the R-Control computer and at each switch location on the CobraNet
network.

R-Control Control Panel

Amplifer Output

Montitor Selection

722-RH 419 REV B   12/06

Summary of Contents for CobraNet

Page 1: ...NetTM User s Manual 19201 Cook Street Foothill Ranch CA 92610 3501 USA Phone 949 588 9997 Fax 949 588 9514 Email sales renkus heinz com Web www renkus heinz com CobraNetTM is a registered trademark of...

Page 2: ...tions 3 Introduction 4 What is CobraNet 4 System Design 4 CobraNet Hardware 5 Input Output Connections 5 Unit Identification 6 Software 7 CNDisco exe CobraNet Discovery Program 7 CobraNet exe 9 R Cont...

Page 3: ...OPEN CAUTION TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE THE COVER NO USER SERVICE ABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL VORSICHT GEFAHR EINES ELEKTRISCHEN SCHLAGES...

Page 4: ...ngle CAT5 cable Because of the use of CAT5 cabling installation costs can be greatly reduced System Design The basic components required for a CobraNet system are shown in the block diagram below Cobr...

Page 5: ...rogram continues uninterrupted CobraNet Hardware Renkus Heinz offers CobraNet in two different configurations The first configuration is installed inside a self powered loudspeaker capable of acceptin...

Page 6: ...wered loudspeaker Indicators CobraNet Ethernet RJ 45 LEDs On each of the RJ 45 Ethernet connectors are two LEDs If the Primary connector is being used then the LEDs on this connector will show activit...

Page 7: ...rocedure 1 Open the CobraNet Discovery program 2 Under the View menu select Options 3 In the IP Address Range box uncheck the Enable Auto Assignment check box 4 Set the Start IP address for the desire...

Page 8: ...devices located on the CobraNet network Here you will see the MAC address and the IP address that has been assigned to each device By using this window you will now be able to see the IP address for...

Page 9: ...ry section of this manual IP Address This is where you enter the IP address of the unit you would like to control The IP Address number for example should look something like 192 168 1 100 The IP addr...

Page 10: ...unicast bundle or there is no transmitter transmitting on that bundle number For the transmitter after entering your desired bundle number the background color of the box will change If the backgroun...

Page 11: ...o channels are coming from The Speaker Monitor path routs audio from the individual speaker amplifier outputs onto the CobraNet network By using R Control in conjunction with CobraNet you have the abi...

Page 12: ...sired loudspeaker and then select Ch 2 in the CobraNet section and that channel will be transmitted back down the CobraNet network R Control and CobraNet Combiner Box RC CAT5BOX Normally the R Control...