42
8. Mode selector switch functions
The mode selection switch is at the front of the alarm system.
Use the mode selection switch to determine the three different operating modes.
HOME
AWAY
OFF
OFF:
The complete alarm system is switched off. The door
bell function is exempted from this.
HOME
AWAY
OFF
HOME:
The alarm system is switched on and the exit delay
starts (duration = 60 seconds). After the end of the exit
delay,
only alarm zone 1
is armed.
HOME
AWAY
OFF
AWAY:
The alarm system is switched on and the exit delay
starts (duration = 60 seconds). After the end of the exit
delay,
both alarm zones
are armed.
During the exit delay, the status LED “EXIT”
flashes quickly
. After the end of the
exit delay, there is a short signal sound (depending on the position of jumper B).
When the alarm system is armed, the status LED “EXIT”
flashes slowly
.