Renishaw TONiC T100x RGSZ Installation Manual Download Page 7

5

Scale application

There are two versions of applicator for use with RGSZ20 scale:  
side mounted (A-9653-0182) and top mounted (A-9653-0273).

1

Allow scale to acclimatize to installation environment prior to installation.

2

Mark out ‘START’ and ‘FINISH’ points for the scale on the axis substrate - ensure that there is room 
for the end clamps (see ‘RGSZ20-S installation drawing’). 

3

Thoroughly clean and degrease the substrate using recommended solvents (see 'Storage and handling').  
Allow substrate to dry before applying scale.

4

Mount the appropriate scale applicator to the readhead mounting bracket using M2.5 screws.  
Place the shim supplied with the readhead between the applicator and substrate to set the  
nominal height. 

NOTE: Scale applicator can be mounted either way round  

to enable easiest orientation for scale installation.

  Move axis to ‘START’ of travel. 

  Begin to remove the backing paper from 

the scale and insert into the applicator 
up to the ‘START’ point (as shown).
A-9653-0182 shown

End clamps

A-9523-4015 is an end clamp kit designed to be used with Renishaw RGSZ scale.

NOTE:  End clamps can be mounted before or after readhead installation.

Ensure that excess glue is wiped away from scale as 
it may affect the readhead signal level.

  The end clamp features two small regions 

of contact adhesive. These will temporarily 
hold the end clamp in position while the  
glue cures. Remove the backing tape  
from either side.

15 mm

  Remove the lacquer coating from the last 

15 mm of each end of the scale with a knife 
and clean with one of the recommended 
solvents (see ‘Storage and handling’).

4

Immediately position end clamp 
over the end of the scale.
Allow 24 hours at 20 °C  
for full cure.

  Thoroughly mix up a sachet of glue 

(A-9531-0342) and apply a small amount 
to the underside of the end clamp.

  Ensure that the end of the scale is in line with the ‘START’ position on the axis and apply 

finger pressure via a clean lint-free cloth to ensure scale end adheres well to substrate. 
A-9653-0182 shown

  Slowly and smoothly move the applicator through the entire axis of travel, ensuring that the 

backing paper is pulled manually from the scale and does not catch under the applicator. 

  Remove applicator carefully and, if necessary, adhere remaining scale manually.  

Apply firm finger pressure via a clean lint-free cloth along the length of the scale after 
application to ensure complete adhesion. 

10   Clean the scale using Renishaw scale wipes (A-9523-4040) or a clean, dry, lint-free cloth. 

11   Fit end clamps (see ‘End clamps’ section).

12   Allow 24 hours for complete adhesion of scale before fitting reference mark selector magnet  

and limit magnets.

Scale

‘Splitter screw’

Scale  

(attached to substrate)

Backing paper

Mounting bracket

Direction of scale application

Limit 
stop

M2.5 mounting holes

‘START’ point

TONiC RGSZ installation guide

Summary of Contents for TONiC T100x RGSZ

Page 1: ...RSLM high accuracy linear encoder Installation guide M 9653 9154 05 B TONiC T100x RGSZ linear encoder system...

Page 2: ...ication 5 End clamps 5 TONiC interface drawing 6 TONiC quick start guide 6 System connection 7 Readhead mounting and alignment 8 Reference mark selector and limit magnet installation 8 System calibrat...

Page 3: ...oHS Patents Features of Renishaw s encoder systems and similar products are the subjects of the following patents and patent applications EP0748436 US5861953 EP1173731 US6775008B2 JP4750998 CNCN100543...

Page 4: ...nstall scale within 18 months of manufacture date Humidity 70 C 0 C Operating 2 Storage 70 C 20 C UHV readhead Bakeout 120 C 95 relative humidity non condensing to EN 60068 2 78 Methylated Spirits Ace...

Page 5: ...ius R 10 Static bend radius 4 2 5 0 2 5 Set up LED CAL AGC LED A 0 6 Pitch tol 1 35 23 11 5 6 min 18 16 7 8 7 8 2 off mounting holes M2 5 through counterbored 3 x 2 75 deep from alternative mounting f...

Page 6: ...ition at extent of travel RGSZ20 S 6 05 0 1 RGSZ20 P 6 2 0 1 Q limit magnet Nominal Q limit trigger point 3 20 0 5 0 2 100 F Reference mark selector magnet Reference mark spacing 50 30 Ra 3 2 13 End c...

Page 7: ...temporarily hold the end clamp in position while the glue cures Remove the backing tape from either side 1 5 m m 1 Remove the lacquer coating from the last 15 mm of each end of the scale with a knife...

Page 8: ...until the CAL LED on the readhead switches off Install and align the readhead to maximise signal strength over the full axis travel as indicated by the readhead and interface set up LEDs readhead Gre...

Page 9: ...head screws 2 Taking care not to touch the pins plug the connector into the socket in the interface ensuring correct orientation as shown 3 Refit the cover plate ensuring the cable ferrule is located...

Page 10: ...the readhead and be sufficiently stiff to prevent deflection or vibration of the readhead during operation Readhead set up Ensure that the scale readhead optical window and mounting face are clean and...

Page 11: ...AL routine and is ready for operation u If the CAL LED continues double flashing after passing the chosen reference mark many times it is not detecting the reference mark Ensure that the correct readh...

Page 12: ...connected Case 5 V Power 5 V Sense 0 V Power 0 V Sense Vp Vq VX CAL Inner shield Outer shield V1 V2 V0 Interface Ti0000 NOTE TD maximum speeds are resolution dependent as defined above Output connect...

Page 13: ...Field Ground The inner shield should be connected to 0 V at receiving electronics only Care should be taken to ensure that the inner and outer shields are insulated from each other If the inner and o...

Page 14: ...tor P Q Active high or Active low P Q Repeatability 0 1 mm Length of limit actuator Incremental 2 channels A and B in quadrature 90 phase shifted Reference NOTE No limits on TD interfaces P limit beco...

Page 15: ...adius UL recognised component UHV Tin coated braided single screen FEP core insulation Maximum cable length Readhead to interface 10 m Interface to controller Renishaw encoder systems have been design...

Page 16: ...site at www renishaw com contact M 9653 9154 05 RENISHAW and the probe symbol used in the RENISHAW logo are registered trade marks of Renishaw plc in the United Kingdom and other countries apply innov...

Reviews: