BR-SERIES
5
Specifications may be subject to change without notice.
INDOOR UNIT
Duct Mounted or Thru-the-Wall
SPECIFICATIONS
Ventilation Type:
Static plate, heat and humidity transfer
Typical Airflow Range:
50-140 CFM
Standard Features:
Painted cabinet
Line-cord power supply
Built-in control
Unit may be mounted in any orientation
Control:
Built-in proportional runtime control and switched
terminals for furnace/AC interconnect
Filters:
Total qty. 2, MERV 8, spun-polyester media:
10 1/2" x 10 1/2" x 1"
Unit Dimensions & Weight:
33 1/2" L x 19 1/4" W x 13 1/2" H
48 lbs.
Max. Shipping Dimensions & Weight (in carton):
32" L x 22" W x 18" H
60 lbs.
Motor(s):
Qty. 1, Double-shaft standard motor
Accessories:
Backdraft damper 6"
Wall cap 6" - white, brown
Exterior thru-the-wall installation kit
Duct collar kit
UNIT DIMENSIONS
UNIT MOUNTING & APPLICATION
Can be mounted in any orientation. If duct-mounted,
airstreams cannot be switched. If mounted with
exterior Thru-the-wall installation kit, the RA/EA
airstreams are switched with the OA/FA airstreams.
If four ducts are connected using duct collar kit,
airstreams may be switched.
AIRFLOW CONFIGURATION
Available as shown in dimension drawing.
30 7/8" Overall
33 1/4" Overall
(with Duct Collars)
28 7/8" Case
20 3/8"
2 1/8"
5 3/4"
1 1/8"
EA (TW)
FA (DH)
OA (TW)
RA (DH)
Cut Hole in Duct
(Minimum Size)
36" Line Cord
2 1/4" Typ.
CL 4 5/8"
CL 6 1/8"
FA (TW)
EA (DH)
EA (TW) FA (DH)
RA (TW)
OA (DH)
OA (TW) RA (DH)
CL 5 1/8"
13 3/8" Case
13 3/8" Overall
18 1/2" Minimum
Service Area
18 1/8" Minimum
Service Area
Door
Swing
24V AC
Control
Terminal
Proportional
Runtime
Control
6" Typ.
8" Typ.
18 1/8" Case
CL 4 1/2"
19 1/8" Overall
1/2"
5/8"
LEFT VIEW
TOP VIEW
FRONT VIEW
RIGHT VIEW
Model: BR130
Drawing Type: Unit Dimension
Version: MAR16
ABBREVIATIONS
EA: Exhaust Air to outside
OA: Outside Air intake
RA: Room Air to be exhausted
FA: Fresh Air to inside
TW: Thru Wall
DH: Duct Hung
INSTALLATION ORIENTATION
Unit may be installed in any
orientation.
NOTE
1.UNLESS OTHERWISE SPECIFIED,
DIMENSIONS ARE ROUNDED TO THE
NEAREST EIGHTH OF AN INCH.
2. SPECIFICATIONS MAY BE SUBJECT
TO CHANGE WITHOUT NOTICE.
ELECTRICAL DATA
HP
Volts
HZ
Phase
Input Watts
FLA
0.1
120
60
Single
121 @ 124 CFM
1.3
UNIT PERFORMANCE
CORE PERFORMANCE
Airflow CFM
ESP in H
2
0
Temp EFF%
Total EFF%
Winter/Summer*
52
0.70
82
78/65
69
0.60
80
75/62
94
0.50
76
71/57
113
0.40
74
68/53
132
0.30
71
65/49
141
0.20
70
63/47
148
0.10
69
62/46
* See HVI certification ratings on page 164 of RenewAire’s Full Line Volume XVIII Catalog.
Note:
Electric Duct Heater and Indirect Gas-Fired Duct Furnace are not available on the BR130.
130
BR
Energy Recovery Ventilator
Standard
Download specification at:
renewaire.com/specifications