BR70 AND BR130 INFO

CERTIFIED PERFORMANCE

SPECIFICATIONS

ENERGY EXCHANGE SYSTEM 

 

Cross flow fixed-plate enthalpic heat exchanger  
core; engineered, proprietary resin-media 
composite. Moderates both temperature and 
humidity extremes.

CERTIFIED PERFORMANCE 

See Performance Report

ACCESS DOOR 

Front panel opens to provide access to filters, 
blowers, and heat exchanger. Snap latches and 
hinges provided for easy service.

INSULATION

 

One inch foil-faced EPS foam throughout. 

DUCT CONNECTIONS 

Insulating double collars with 6" and 8" round 
connections for flexible or rigid duct work.

MOUNTING OPTIONS 

Unit may be mounted to duct or wall using integral 
mounting flange with hanging bracket kit provided.

BLOWER/MOTOR 

A single high efficiency PSC motor directly drives 
two centrifugal blowers for quiet operation.

FILTERS  

Cleanable polyester air filters for both exhaust and 
fresh airstreams.

DEFROST 

Passive frost-free design under most  
residential conditions. 

WARRANTY 

Ten year limited warranty on heat exchange 
core; five year limited warranty against defects 
in material and workmanship on all other 
components.

RENEWAIRE.COM

  1.800.627.4499  

164

OPTIONS & ACCESSORIES

HVI TESTED/CERTIFIED

PER CSA C439

Electrical Requirements Volts 120 Amps 3.3
Exhaust Air Transfer Ratio = 0.0% @ 0.2 in. wg (50 PA) and 2.0% @ 0.4 in. wg (100 Pa)

EV300 - Ventilation Performance

Ext. Static Pressure

Net Supply Airflow

Gross Airflow

Supply

Exhaust

Pa

in. wg

L/S

CFM

L/S

CFM

L/S

CFM

100

0.4

147

311

150

317

143

303

125

0.5

139

295

142

301

133

283

150

0.6

131

277

133

282

125

265

175

0.7

121

256

123

261

108

230

200

0.8

101

215

103

219

94

198

225

0.9

90

191

92

195

74

156

250

1.0

80

170

82

174

47

99

EV300 - Energy Performance

Supply 

Temperature

Net Airflow

Average Power 

Watts

Sensible Recovery 

Efficiency %

Adjusted Sensible 

Recovery  

Efficiency %

Net Moisture 

Transfer %

L/S

CFM

    Heating

32°

139

297

315

67

73

54

    Cooling

Total  

Recovery Efficiency %

Adjusted Total  

Recovery Efficiency %

35°

95°

138

294

313

46

49

EV200 - Energy Performance

Supply 

Temperature

Net Airflow

Average Power 

Watts

Sensible Recovery 

Efficiency %

Adjusted Sensible 

Recovery  

Efficiency %

Net Moisture 

Transfer %

L/S

CFM

    Heating

32°

85

181

157

78

84

62

    Cooling

Total  

Recovery Efficiency %

Adjusted Total  

Recovery Efficiency %

35°

95°

85

180

155

52

54

Electrical Requirements Volts 120 Amps 1.5
Exhaust Air Transfer Ratio = 3.0% @ 0.2 in. wg (50 PA) and 3.0% @ 0.4 in. wg (100 Pa)

EV200 - Ventilation Performance

Ext. Static Pressure

Net Supply Airflow

Gross Airflow

Supply

Exhaust

Pa

in. wg

L/S

CFM

L/S

CFM

L/S

CFM

25

0.1

97

207

100

213

109

232

50

0.2

90

192

93

199

104

221

75

0.3

88

186

90

192

101

216

100

0.4

83

176

85

181

96

204

125

0.5

79

168

81

173

88

187

150

0.6

70

149

72

154

76

162

175

0.7

57

122

59

126

68

145

EV240 - Energy Performance

Supply 

Temperature

Net Airflow

Average Power 

Watts

Sensible Recovery 

Efficiency %

Adjusted Sensible 

Recovery  

Efficiency %

Net Moisture 

Transfer %

L/S

CFM

    Heating

32°

111

236

216

74

80

57

    Cooling

Total  

Recovery Efficiency %

Adjusted Total  

Recovery Efficiency %

35°

95°

108

229

213

53

56

Electrical Requirements Volts 120 Amps 3.3
Exhaust Air Transfer Ratio = 2.4% @ 0.2 in. wg (50 PA) and 2.3% @ 0.4 in. wg (100 Pa)

EV240 - Ventilation Performance

Ext. Static Pressure

Net Supply Airflow

Gross Airflow

Supply

Exhaust

Pa

in. wg

L/S

CFM

L/S

CFM

L/S

CFM

25

0.1

125

267

129

272

132

279

50

0.2

121

258

124

264

126

268

75

0.3

118

250

120

255

121

257

100

0.4

114

240

116

246

117

247

125

0.5

108

228

111

234

110

233

150

0.6

101

214

103

219

102

217

175

0.7

92

195

94

200

93

196

200

0.8

80

169

82

174

79

168

EV130 - Energy Performance

Supply 

Temperature

Net Airflow

Average Power 

Watts

Sensible Recovery 

Efficiency %

Adjusted Sensible 

Recovery  

Efficiency %

Net Moisture 

Transfer %

L/S

CFM

    Heating

32°

61

130

102

71

75

53

    Cooling

Total  

Recovery Efficiency %

Adjusted Total  

Recovery Efficiency %

35°

95°

61

130

102

48

51

Electrical Requirements Volts 120 Amps 1.3
Exhaust Air Transfer Ratio = 2.0% @ 0.2 in. wg (50 PA) and 2.0% @ 0.4 in. wg (100 Pa)

EV130 - Ventilation Performance

Ext. Static Pressure

Net Supply Airflow

Gross Airflow

Supply

Exhaust

Pa

in. wg

L/S

CFM

L/S

CFM

L/S

CFM

25

0.1

77

165

79

168

79

168

50

0.2

72

153

73

156

73

156

75

0.3

64

137

66

140

66

140

100

0.4

59

126

61

129

61

129

125

0.5

49

104

50

106

50

106

150

0.6

37

79

38

81

38

81

EV90/GR90 - Energy Performance

Supply 

Temperature

Net Airflow

Average  

Power Watts

Sensible Recovery 

Efficiency %

Adjusted Sensible 

Recovery  

Efficiency %

Net Moisture 

Transfer %

L/S

CFM

    Heating

32°

42

90

46

72

77

37

    Cooling

Total  

Recovery Efficiency %

Adjusted Total  

Recovery Efficiency %

35°

95°

42

90

44

46

48

Electrical Requirements Volts 120 Amps 0.35
Exhaust Air Transfer Ratio = 2.0% @ 0.2 in. wg (50 PA) 

and 2.0% @ 0.4 in. wg (100 Pa)

EV90/GR90 - Ventilation Performance

Ext. Static Pressure

Net Supply Airflow

Gross Airflow

Supply

Exhaust

Pa

in. wg

L/S

CFM

L/S

CFM

L/S

CFM

25

0.1

53

113

54

115

52

109

50

0.2

46

98

47

100

46

97

75

0.3

40

85

41

87

40

85

100

0.4

34

73

35

74

34

72

125

0.5

27

58

28

59

28

60

150

0.6

19

40

19

41

22

47

BR130 - Energy Performance

Supply 

Temperature

Net Airflow

Average  

Power Watts

Sensible Recovery 

Efficiency %

Adjusted Sensible  

Recovery  

Efficiency %

Net Moisture  

Transfer %

L/S

CFM

    Heating

32°

58

124

121

72

78

55

    Cooling

Total  

Recovery Efficiency %

Adjusted Total  

Recovery Efficiency %

35°

95°

59

126

121

46

48

Electrical Requirements Volts 120 Amps 1.3
Exhaust Air Transfer Ratio = 1.6% @ 0.2 in. wg (50 PA) and 1.6% @ 0.4 in. wg (100 Pa)

BR130 - Ventilation Performance

Ext. Static Pressure

Net Supply Airflow

Gross Airflow

Supply

Exhaust

Pa

in. wg

L/S

CFM

L/S

CFM

L/S

CFM

25

0.1

70

148

71

151

75

159

50

0.2

66

141

67

143

69

147

75

0.3

62

132

63

134

64

135

100

0.4

53

113

54

115

56

119

125

0.5

44

94

45

96

47

99

150

0.6

32

69

33

70

29

62

175

0.7

24

52

25

53

21

45

EV90P - Energy Performance

Supply 

Temperature

Net Airflow

Average Power 

Watts

Sensible Recovery 

Efficiency %

Adjusted Sensible 

Recovery  

Efficiency %

Net Moisture 

Transfer %

L/S

CFM

    Heating

32°

42

90

44

80

83

64

    Cooling

Total  

Recovery Efficiency %

Adjusted Total  

Recovery Efficiency %

35°

95°

42

90

44

63

71

Electrical Requirements Volts 120 Amps 0.35
Exhaust Air Transfer Ratio = 1.6% @ 0.2 in. wg (50 PA) 

and 2.0% @ 0.4 in. wg (100 PA)

EV90P - Ventilation Performance

Ext. Static Pressure

Net Supply Airflow

Gross Airflow

Supply

Exhaust

Pa

in. wg

L/S

CFM

L/S

CFM

L/S

CFM

25

0.1

51

108

52

110

52

110

50

0.2

47

99

48

101

47

100

75

0.3

41

87

42

89

42

89

100

0.4

35

73

36

75

36

76

125

0.5

26

56

27

57

27

58

150

0.6

20

42

20

42

21

44

165

FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT  

RENEWAIRE.COM 

CERTIFICATIONS & PERFORMANCE

INDEPENDENTLY TESTED

PER CSA C439

Electrical Requirements Volts 120 Amps 1.0
Exhaust Air Transfer Ratio = 3.6% @ 0.2 in. wg (50 PA) and 3.4% @ 0.4 in. wg (100 Pa)

BR70 - Energy Performance

Supply 

Temperature

Net Airflow

Average Power 

Watts

Sensible Recovery 

Efficiency %

Adjusted Sensible 

Recovery  

Efficiency %

Net Moisture 

Transfer %

L/S

CFM

    Heating

32°

32

69

94

66

75

53

    Cooling

Total  

Recovery Efficiency %

Adjusted Total  

Recovery Efficiency %

35°

95°

30

64

94

42

47

BR70 - Ventilation Performance

Ext. Static Pressure

Net Supply Airflow

Gross Airflow

Supply

Exhaust

Pa

in. wg

L/S

CFM

L/S

CFM

L/S

CFM

25

0.1

41

86

42

89

46

97

50

0.2

34

73

35

75

39

84

75

0.3

28

59

29

61

32

69

100

0.4

21

46

22

47

25

53

AHRI 1060

CERTIFIED PERFORMANCE

NOTE:

  SCFM = Standard Cubic Feet per Minute    OACF = Outdoor Air Correction Factor    EATR  = Exhaust Air Transfer Ratio    N/A  = Not Applicable

Energy recovery component certified in accordance with AHRI Standard 1060-2013.
Actual performance in packaged equipment may vary.

Thermal Effectiveness Ratings at 0" Pressure Differential

Nominal Airflow

Sensible

Latent

Total

Net  

Airflow

Net  

Sensible

Net  

Latent

Net  

Total

750    Heating

CFM   Cooling

70%

70%

52%

42%

64%

53%

750 

CFM

70%

70%

52%

42%

64%

53%

563    Heating

CFM   Cooling

74%

74%

59%

49%

69%

58%

563

CFM

74%

74%

59%

49%

69%

58%

Leakage Ratings

Pressure  

Differential

EATR

OACF

Purge Angle or 

Setting

-1 in. H

2

0

1.0%

1.00

N/A

0 in. H

2

0

0.0%

1.02

N/A

1 in. H

2

0

0.0%

1.05

N/A

AHRI-1060 Certified Performance - Model Number L125-G5

Type

Tilt Angle

Nominal Airflow

Pressure Drop

Plate

N/A

100% - 750 SCFM 

75% - 563 SCFM

0.65 in. H

2

0

Thermal Effectiveness Ratings at 0" Pressure Differential

Nominal Airflow

Sensible

Latent

Total

Net  

Airflow

Net  

Sensible

Net  

Latent

Net  

Total

500    Heating

CFM   Cooling

70%

70%

52%

42%

64%

53%

500 

CFM

70%

70%

52%

42%

64%

53%

375    Heating

CFM   Cooling

74%

74%

59%

49%

69%

58%

375

CFM

74%

74%

59%

49%

69%

58%

Leakage Ratings

Pressure  

Differential

EATR

OACF

Purge Angle or 

Setting

-1 in. H

2

0

1.0%

1.00

N/A

0 in. H

2

0

0.0%

1.02

N/A

1 in. H

2

0

0.0%

1.05

N/A

AHRI-1060 Certified Performance - Model Number L85-G5

Type

Tilt Angle

Nominal Airflow

Pressure Drop

Plate

N/A

100% - 500 SCFM 

75% - 375 SCFM

0.65 in. H

2

0

Thermal Effectiveness Ratings at 0" Pressure Differential

Nominal Airflow

Sensible

Latent

Total

Net  

Airflow

Net  

Sensible

Net  

Latent

Net  

Total

350    Heating

CFM   Cooling

70%

70%

52%

42%

64%

53%

350 

CFM

70%

70%

52%

42%

64%

53%

263    Heating

CFM   Cooling

74%

74%

59%

49%

69%

58%

263

CFM

74%

74%

59%

49%

69%

58%

Leakage Ratings

Pressure  

Differential

EATR

OACF

Purge Angle or 

Setting

-1 in. H

2

0

1.0%

1.00

N/A

0 in. H

2

0

0.0%

1.02

N/A

1 in. H

2

0

0.0%

1.05

N/A

AHRI-1060 Certified Performance - Model Number L62-G5

Type

Tilt Angle

Nominal Airflow

Pressure Drop

Plate

N/A

100% - 350 SCFM 

75% - 263 SCFM

0.65 in. H

2

0

Summary of Contents for BR130 SERIES

Page 1: ...INSTALLATION OPERATION MAINTENANCE MANUAL ENERGY RECOVERY VENTILATOR BR70 BR130 RENEWAIRE COM MODEL BR70 MODEL BR130...

Page 2: ...2 13 Maintenance 14 15 TABLE OF CONTENTS There is no known safe level of cigarette smoke Any ventilation system may provide noticeable improvement in spaces where cigarettes are smoked but it cannot b...

Page 3: ...ps 1 3 Exhaust Air Transfer Ratio 1 6 0 2 in wg 50 PA and 1 6 0 4 in wg 100 Pa BR130 Ventilation Performance Ext Static Pressure Net Supply Airflow Gross Airflow Supply Exhaust Pa in wg L S CFM L S CF...

Page 4: ...as shown in dimension drawing 2 1 1 8 36 Line Cord 29 5 8 Overall with Duct Collars 25 1 8 Case 2 1 4 Typ 27 1 8 Overall C L 6 1 8 C L 5 5 8 18 1 8 Case C L 4 1 2 1 2 5 8 19 1 8 Overall 6 Typ 8 Typ 1...

Page 5: ...ion drawing 30 7 8 Overall 33 1 4 Overall with Duct Collars 28 7 8 Case 20 3 8 2 1 8 5 3 4 1 1 8 EA TW FA DH OA TW RA DH Cut Hole in Duct Minimum Size 36 Line Cord 2 1 4 Typ C L 4 5 8 C L 6 1 8 FA TW...

Page 6: ...ith velocities not exceeding 750 fpm at the point in the return air duct where the BR unit is attached An alternate field measurement would be to locate the BR unit where the static pressure measureme...

Page 7: ...rigid un insulated wall mounted units only Ducts from unit to house in unconditioned spaces All ducts from unit to house in unconditioned spaces like attics and crawl spaces must be insulated DUCT SI...

Page 8: ...gh the flue chimney of fuel burning equipment that might be installed in the area affected by this equipment If this unit is exhausting air from a space in which chimney vented fuel burning equipment...

Page 9: ...gure F6 The interior plate is attached to the interior of the wall Using the holes in the plate as a reference cut 6 holes to the outside allowing for a downward tilt to the outside of for 12 of duct...

Page 10: ...ors are generated stale air returns which pick up stale household air to be exhausted should be located in bathrooms and the kitchen A central location such as a hallway is also acceptable but won t c...

Page 11: ...tomatic Proportional Runtime Control All installations include a Primary Operating Control on the unit to ensure appropriate operation of the system The control terminal on the unit must be connected...

Page 12: ...n also be used to determine when filters should be cleaned or changed Use Static Taps to Measure Aiflow Rates See Cross Core Static Drop in MEASURING AIRFLOW table on page 13 Use Damper to Balance Air...

Page 13: ...SCFM of Room Air RA install the high pressure side of your measuring device to the Room Air RA port and the low pressure side to the Exhaust Air EA port If gauge drops below zero reverse tubing connec...

Page 14: ...ERV BR70 AND BR130 RENEWAIRE COM INSTALLATION OPERATION AND MAINTENANCE MANUAL 1 800 627 4499 14 MAINTENANCE SERVICE PARTS BR Units BR70 shown www renewaire com 800 627 4499 support renewaire com...

Page 15: ...mes The primary contact for replacement filters for your RenewAire unit is the installing contractor As an alternative you may wish to produce your own filters following these instructions Filters may...

Page 16: ...8 UNMATCHED VENTILATION SUPPORT As much as our unsurpassed quality and performance our customers can also depend on our professional support staff for swift professional assistance with all their tech...

Reviews: