R01UH0822EJ0100 Rev.1.00
Page 526 of 1041
Jul 31, 2019
RX13T Group
19. Multi-Function Timer Pulse Unit 3 (MTU3c)
(29) Operation When Error Occurs in Reset-Synchronized PWM Mode and Operation is Restarted
in Reset-Synchronized PWM Mode
shows a case in which an error occurs in reset-synchronized PWM mode and operation is restarted in
reset-synchronized PWM mode after re-setting.
Figure 19.171
Error Occurrence in Reset-Synchronized PWM Mode, Recovery in Reset-Synchronized PWM
Mode
(1) to (10) are the same as in
(11) Set MTU output using the MPC and port mode registers (PMR) corresponding to the I/O ports.
(12) Restart operation by setting the TSTRA register.
(13) The reset-synchronized PWM waveform is output on compare match occurrence.
(3)
TMDR
(RPWM)
Hi-Z
Hi-Z
Hi-Z
MTU module output
(1)
Reset
(2)
TOCR
(4)
TOER
(1)
(5)
MPC
(MTU)
(7)
Match
(8)
Error
occurs
(9)
Port
output
(10)
TSTR
(0)
(12)
TSTR
(1)
(13)
Match
MTIOC3A
MTIOC3B
MTIOC3D
PORT output
Pxx
Pxx
Pxx
(6)
TSTR
(1)
(11)
MPC
(MTU)