R01UH0822EJ0100 Rev.1.00
Page 506 of 1041
Jul 31, 2019
RX13T Group
19. Multi-Function Timer Pulse Unit 3 (MTU3c)
(6) Operation When Error Occurs in Normal Mode and Operation is Restarted in Reset-
Synchronized PWM Mode
shows a case in which an error occurs in normal mode and operation is restarted in reset-synchronized
PWM mode after re-setting.
Figure 19.148
Error Occurrence in Normal Mode, Recovery in Reset-Synchronized PWM Mode
(1) to (13) are the same as in
(14) Select the reset-synchronized PWM output level and enable or disable cyclic output with registers TOCR1A and
TOCR2A.
(15) Set reset-synchronized PWM mode.
(16) Enable output in MTU3 and MTU4 with the TOERA register.
(17) Set MTU output using the MPC and port mode registers (PMR) corresponding to the I/O ports.
(18) Restart operation by setting the TSTRA register.
(1)
Reset
MTU module output
Hi-Z
Hi-Z
Hi-Z
(2)
TMDR
(normal)
(3)
TOER
(1)
(4)
TIOR
(1 init
0 out)
(6)
TSTR
(1)
(7)
Match
(8)
Error
occurs
(10)
TSTR
(0)
(11)
TIOR
(0 init
0 out)
(12)
TIOR
(disabled)
(13)
TOER
(0)
(14)
TOCR
(15)
TMDR
(RPWM)
(16)
TOER
(1)
(18)
TSTR
(1)
MTIOC3A
MTIOC3B
MTIOC3D
PORT output
Pxx
Pxx
Pxx
(9)
Port
output
(5)
MPC
(MTU)
(17)
MPC
(MTU)