9
CHAPTER 2 INSTALLATION
(4) Connect IE-78044-R-EM to the break board.
Connect connectors CN1 and CN2 on IE-78044-R-EM to mating connectors CN1 and CN2 on the break board.
Secure the connectors with the screws supplied as accessories.
Caution
:
Be sure to connect CN1 and CN2 securely.
(5) To use the user clock, mount the main system clock to the emulation board and the subsystem clock to the break
board by using the component block (refer to
CHAPTER 4 SETTING CLOCK
).
(6) Set the mask option by using the DIP switch on IE-78044-R-EM (refer to
3.1 Setting Mask Option
).
(7) Connect connectors CN3 and CN4 for IE-78044-R-EM to mating connectors CN3 and CN4 on the connector board,
supplied with the optional emulation probe.
(8) Connect IE-78044-R-EM to the slot for the master board for the IE-78000-R’s housing (connect the break board
to the second slot from the right, and IE-78044-R-EM to the third slot from the right).
(9) Connect cables J1 and J2.
(10) Confirm the positions for the boards. Attach the top cover.
(11) Connect connector CN5, on top of IE-78000-R, to the mating connector CN5 on the emulation board. Secure the
connectors with screws.