15
5.2
Diagnostic Test Procedure Using the Test Program
Insert the CD-R (HS2268EPI61SR supplied with the E6000) into the CD-ROM drive of the host
computer by pressing the Shift key, move the current directory to <Drive>:\Diag with a command
prompt, and enter one of the following commands according to the PC interface board used to
initiate the test program:
1. ISA bus interface board (HS6000EII01H)
> TM2268 –ISA (RET)
2. PCI bus interface board (HS6000EIC01H or HS6000EIC02H)
> TM2268 –PCI (RET)
3. PCMCIA interface card (HS6000EIP01H)
> TM2268 –PCCD (RET)
The HDI must be installed before the test program is executed.
Be sure to initiate the test program from <Drive>:\Diag. Do not initiate it from a directory other
than <Drive>:\Diag, such as > <Drive>:\Diag\TM2268 –ISA (RET). If the test program is
initiated when the current directory is not <Drive>:\Diag, the test program will not operate
correctly.
When –S is added to the command line such as > TM2268 –ISA –S (RET), steps 1 to 20 will be
repeatedly executed. To stop the execution, enter Q.
Notes: 1. When the CD-R is inserted into the CD-ROM drive without pressing the Shift key, the
HDI installation wizard is automatically started.
In such a case, exit the HDI installation wizard.
2.
<Drive> is a drive name for the CD-ROM drive.
3.
Do not remove the CD-R from the CD-ROM drive during test program execution.