CPX4 AC-PLC Evaluation Kit M02D2 RTK0EE0009D02001BJ
3
.
Interface Specifications
R30UZ0165EJ0100 Rev.1.00
Page 37 of 53
July 01, 2021
Table 3-19 RX651MCU terminal connection 2/2
Terminal
number
Terminal name
MCU(RX651) side
Connection destination
Remark (Recommended setting when not in use)
51
PC1
I/O
CN304-5
Built-in pull-up when not in use
52
PC0
O
CN300-1
Output HIGH when not in use
53
PB7
O
CN300-4
Input port when not used
54
PB6/
I/O
CN300-6
Input port when not used
55
PB5
I
CN300-8
Built-in pull-up when not in use
56
PB4
I
CN300-2
Built-in pull-up when not in use
57
PB3
I
CN300-3
Built-in pull-up when not in use
58
PB2
I/O
CN300-5
Built-in pull-up when not in use
59
PB1
I/O
CN300-7
Built-in pull-up when not in use
60
VCC
-
3.3V
-
61
PB0
I/O
-
Built-in pull-up when not in use
62
VSS
-
GND
-
63
PA7
I/O
-
Input port when not used
64
PA6
I/O
-
Input port when not used
65
PA5
O
-
Input port when not used
66
PA4
I/O
RX651-70
Input port when not used
67
PA3
I/O
-
Built-in pull-up when not in use
68
PA2
I
-
Built-in pull-up when not in use
69
PA1
O
-
Built-in pull-up when not in use
70
PA0
I
RX651-66
Built-in pull-up when not in use
71
PE7
I
CN301-9
Built-in pull-up when not in use
72
PE6
I
CN301-10
Built-in pull-up when not in use
73
PE5
I
-
Built-in pull-up when not in use
74
PE4
I
-
Built-in pull-up when not in use
75
PE3
I
-
Built-in pull-up when not in use
76
PE2
I
-
Built-in pull-up when not in use
77
PE1
I
-
Built-in pull-up when not in use
78
PE0
I
-
Built-in pull-up when not in use
79
PD7
I
CN301-2
Built-in pull-up when not in use
80
PD6
I
CN301-3
Built-in pull-up when not in use
81
PD5
I/O
CN301-4
Built-in pull-up when not in use
82
PD4
I
CN301-5
Built-in pull-up when not in use
83
PD3/IRQ3
I/O
CN301-6
Built-in pull-up when not in use
84
PD2
I/O
CN301-8
Built-in pull-up when not in use
85
PD1
I/O
-
Built-in pull-up when not in use
86
PD0
I/O
CN301-11
Built-in pull-up when not in use
87
P47
I
SW301-4
Built-in pull-up when not in use
88
P46
I
SW301-3
Built-in pull-up when not in use
89
P45
I
SW301-2
Built-in pull-up when not in use
90
P44
I
SW301-1
Built-in pull-up when not in use
91
P43
I
SW302-4
Built-in pull-up when not in use
92
P42
I
SW302-3
Built-in pull-up when not in use
93
P41
I
SW302-2
Built-in pull-up when not in use
94
VREFL0
-
GND
-
95
P40
I
SW302-1
Built-in pull-up when not in use
96
VREFH0
-
3.3V
-
97
AVCC0
-
3.3V
-
98
P07
I
-
Built-in pull-up when not in use
99
AVSS0
-
GND
100
P05
I
-
Built-in pull-up when not in use