The following table gives an overview of the power consumption of
your electrical equipment.
consumer
power[ W ]
current@ 12V [ A ]
Dynon D180
19
1,5
FlymapL
42
3,5
Garmin GPS696
15
1,1
Garmin aera 500
10
3,6
Becker AR6201
6
1,6
Becker BXP6401
14
0,4
PM3000
10
0,8
ACL (LED)
37
3,1
position lights
12
1,0
landing lights (LED)
24
2,0
Electric fuel pump
20
1,7
Elevator trim
4
0,3
flap drive
25
2,1
12V receptacle
12
1,0
Power shortage makes itself felt primarily by malfunctioning of the
transceiver in transmit mode. There is no transmission possible.
Other equipment, e.g. the DYNON D180, will display a low voltage
warning. To prevent electrical shortage, following procedure is
recommended:
‚
switch off all non-essential electrical loads
‚
engine speed on ground min. 2.500RPM
‚
engine speed in flight min. 4.000RPM
Low temperatures reduce the capacity to increase the on-board
battery and its internal resistance. This may cause some trouble in
the cold season. If the aircraft is not operated in winter time REMOS
recommends storing the battery in a warm and dry place.