Manual operation 

The unit can be manually operated, if, for example, the 
infrared remote control is not functioning properly or 
has been lost.  

Open the air intake grille of the indoor unit and press 
the button on the right side.  
The following operating modes are then activated: 

MODUS =  Automatic  
TEMP. = 24 

°C,  FAN  = Automatic, 

SWING =  On, 

 

TIMER =  Off. 

Shutting Down the Unit 

 

Temporary shutdown 

1.  Let the unit run in cooling mode for half an hour. 
2.  Switch the indoor unit off using the remote control. 
3.  Disconnect the system with the main switch or fuse 

protection from the power supply. 

4.  Check the indoor unit for visible damage. 
5. Clean the indoor unit as described in the 

“Maintenance and Service” section. 

By pressing the lower RESET button, the remote control can be reset. Afterwards, the 
time must be programmed (see “CLOCK button“). 

RESET button

 

Functional process 

RESET 

5 sec. 

Clock setting 

Shown on the display 
Malfunctions are shown as a code on the display of the 
indoor unit. After the malfunction has been fixed, the con-
trol mechanism operates with the previously set parame-
ters. 
 
F1 

Room air sensor or defective 

F2 

Frost protection sensor defective/activated 

HI Defrost 

phase 

Receiver 

Dehumidifying mode 

On / Off 

Circulation mode 

Automatic mode 

Display for target 

value and display 

Heating mode 

Cooling mode 

Manual air distribution 

There are individually adjustable air directing plate fins 
on the air outlet side for horizontally distributing the air. 

*

 

Never adjust the fins when the unit is in automatic 
swing mode! Do not reach into the unit! 

There is a risk of injuring your hand on the fan 
motor.

 

Display on the indoor unit 

The display is lit up depending on the current settings. 
During operation, the on / off display and the selected 
mode and the target temperature are displayed. 

Display of fan 
speed 

Summary of Contents for RXW 350

Page 1: ...REMKO powerful like a bear REMKO RXW 350 480 Wall units Edition GB R05 Operation Technology Spare Parts...

Page 2: ......

Page 3: ...nel 13 Installation 13 Electrical Connection 15 Wiring Diagram 15 Condensation Connection 15 Prior to Initial Operation 16 Initial Operation 16 Customer Service and Guarantee 17 Environment and Recycl...

Page 4: ...ate the unit exclusively within the permissible op erating ranges Observe surrounding temperatures Make sure that the unit is kept at a safe distance from flammable objects Ensure that no foreign obje...

Page 5: ...lect the operating mode The indoor unit has 5 modes Automatic In this mode the unit operates in cooling or heat ing mode Cooling In this mode the warm room air is cooled down to the desired temperatur...

Page 6: ...the display no longer blinks CLOCK button Functional process CLOCK CLOCK By pressing the ON OFF button the air conditioning unit is switched on and off The settings and setting values programmed befor...

Page 7: ...rature The desired room temperature is set in 1 C increments with the TEMP UP DN button If the temperature is 1 C above the set target temperature the indoor unit begins to cool the room air If the ro...

Page 8: ...is button must be pressed again The swing function improves the air distribu tion in the room Functional process SWING SWING SLEEPING button With this button a program is activated that increases the...

Page 9: ...med see CLOCK button RESET button Functional process RESET 5 sec Clock setting Shown on the display Malfunctions are shown as a code on the display of the indoor unit After the malfunction has been fi...

Page 10: ...ecured against being inadvertently switched on System Structure The indoor unit is connected to the outdoor unit with re frigerant pipes Outdoor unit Refrigerant pipes Outdoors Indoors Condenser fan S...

Page 11: ...the unit to start Polarity of batteries incorrect after replacement Is the polarity correct Insert batteries with the correct polarity Transmission distance too great reception blocked Is there a tran...

Page 12: ...lectr nominal current consumption cooling A 4 91 6 91 Electr nominal current consumption heating A 4 99 Refrigerant connection injection pipe Inches mm 1 4 6 35 Refrigerant connection suction pipe Inc...

Page 13: ...ust meet the relevant re quirements The power supply is only connected to the outdoor unit The control line to the indoor unit should be placed together with the refrigerant pipe Make sure that the el...

Page 14: ...When assembling the unit observe the bending radii of the refrigerant pipes and never bend the hose in the same place twice This may cause the pipe to become brittle or crack 4 Remove the preinstalle...

Page 15: ...fin exchanger of the indoor unit during cooling operation because tempera tures below the dew point are reached The indoor unit is equipped with a condensate collector and a condensation hose for the...

Page 16: ...a tion must be performed using the certificate and must be documented Following initial operation the operator must be trained in its operation and the initial operation log given to him Prior to Init...

Page 17: ...the guarantee becomes null and void Customer Service and Guarantee For the guarantee to be valid the purchaser or his cus tomer must completely fill out the guarantee certificate enclosed with all un...

Page 18: ...ation Name Street Postal code country city Telephone Fax Test of cooling cycle Result Visual check Setup of outdoor unit and indoor unit 5 good 4 poor Heat exchanger insulation pipes 5 good 4 poor Ele...

Page 19: ......

Page 20: ...REMKO GmbH Co KG Air Conditioning and Heating Technology D 32791 Lage Im Seelenkamp 12 D 32777 Lage P O Box 1827 Phone 49 52 32 606 0 Fax 49 52 32 606 260 E mail export remko de Internet www remko de...

Reviews: