9
Manual operation
The unit can be manually operated, if, for example, the
infrared remote control is not functioning properly or
has been lost.
Open the air intake grille of the indoor unit and press
the button on the right side.
The following operating modes are then activated:
MODUS = Automatic
TEMP. = 24
°C, FAN = Automatic,
SWING = On,
TIMER = Off.
Shutting Down the Unit
Temporary shutdown
1. Let the unit run in cooling mode for half an hour.
2. Switch the indoor unit off using the remote control.
3. Disconnect the system with the main switch or fuse
protection from the power supply.
4. Check the indoor unit for visible damage.
5. Clean the indoor unit as described in the
“Maintenance and Service” section.
By pressing the lower RESET button, the remote control can be reset. Afterwards, the
time must be programmed (see “CLOCK button“).
RESET button
Functional process
RESET
5 sec.
Clock setting
Shown on the display
Malfunctions are shown as a code on the display of the
indoor unit. After the malfunction has been fixed, the con-
trol mechanism operates with the previously set parame-
ters.
F1
Room air sensor or defective
F2
Frost protection sensor defective/activated
HI Defrost
phase
Receiver
Dehumidifying mode
On / Off
Circulation mode
Automatic mode
Display for target
value and display
Heating mode
Cooling mode
Manual air distribution
There are individually adjustable air directing plate fins
on the air outlet side for horizontally distributing the air.
*
Never adjust the fins when the unit is in automatic
swing mode! Do not reach into the unit!
There is a risk of injuring your hand on the fan
motor.
Display on the indoor unit
The display is lit up depending on the current settings.
During operation, the on / off display and the selected
mode and the target temperature are displayed.
Display of fan
speed