Data specific to indoor unit
BL 264 DC IT
BL 354 DC IT
Application area (room volume), approx.
m
3
80
110
Adjustment range, room temperature
°C
+17 to +30
Air flow volume per stage
m
3
/h
400/500/600
Sound pressure level per stage
5)
dB (A)
29/35/42
28/31/41
Sound pressure level, silent mode
dB (A)
189
20
Sound power level max.
dB(A)
54
53
Enclosure class
IP
IPX0
Condensate drainage connection
mm
16
Dimensions: H/W/D
mm
292/792/201
Weight
kg
8.5
EDP no.
1629270
1629362
5)
At distance of 1m in the open air; specified values are maximum values
Data specific to outdoor unit
BL 264 DC AT
BL 354 DC AT
Power supply
V/Ph/
Hz
230/1~/50
Operating range, cooling
°C
+5 to +48
Operating range, heating
7)
°C
+5 to +32
Air flow rate, max.
m
3
/h
600
Enclosure class
IP
IP24
Sound power level max.
dB (A)
61
62
Sound pressure level
5)
dB (A)
53
54
Refrigerant
6)
R32
Refrigerant, basic quantity
kg
0.56
CO
2
equivalent
t
0.378
Operating pressure, max.
kPa
4300/2500
4150/1150
Refrigerant piping, max. length
m
3, 5, 8
Refrigerant piping, max. height difference
m
5
Dimensions: H/W/D
mm
530/705/279
Weight
kg
22.5
EDP no.
1629269
1629361
5)
At distance of 1m in the open air; specified values are maximum values
6)
Contains greenhouse gas according to Kyoto protocol, GWP 2088
7)
This can be extended to -20 °C with the appropriate accessory kit
REMKO BL series