background image

© 2019 Pinnacle Climate Technologies, Inc. 

Silent Drive Forced Air Heater User’s Manual 

NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR 

WHILE CONNECTED TO A POWER SOURCE

11

TROUBLESHOOTING GUIDE

Problem

Possible Cause

Solution

Heater Ignites, but main PCB shuts 

off after a short period of time. 

LED display shows “E1.”

1.  Dirty fuel filter.

2.  Nozzle is dirty.

3.  Photocell lens is dirty.

4.  Photocell not installed properly.

5.  Photocell is defective.

6.  Improper electrical connection 

between main PCB and photocell.

1.  Clean / replace fuel filter.

2.  Clean / replace Nozzle.

3.  Clean / replace photocell.

4.  Adjust photocell position

5.  Replace photocell

6.  Check wiring connections.

Heater will not operate or motor 

runs for a short time.

LED display shows “E1.”

1.  No kerosene in the fuel tank.

2.  Corroded spark plug or incorrect 

plug gap.

3.  Dirty fuel filter.

4.  Dirty nozzle.

5.  Moisture in fuel tank. 

6.  Improper electrical connection 

between transformer and circuit 

board.

7.  Ignitor wire not connected to 

spark plug.

8.  Defective ignitor. 

1.  Fill tank with fresh kerosene.

2.  Clean / replace spark plug. 

3.  Clean / replace fuel filter. 

4.  Clean / replace nozzle.

5.  Rinse fuel tank with clean, fresh 

kerosene.

6.  Inspect all electrical connections. 

7.  Re-attach ignitor wire to spark 

plug. 

8.  Replace ignitor.  

Fan does not operate when heater 

is plugged in and power switch is 

in the “ON” position. LED display 

shows “E1” or “E2.”

1.  Thermostat is set too low.

2.  Broken electrical connection 

between main PCB and motor. 

1.  Rotate thermostat to a higher 

setting

2.  Inspect all electrical connections.

Poor combustion and / or excess 

soot production. 

1.  Dirty fuel filter.

2.  Poor quality of fuel.

3.  PSI is too high or too low. 

1.  Clean / replace fuel filter.

2.  Flush fuel tank and refuel heater.

3.  Use proper pressure. 

Heater does not turn on and the 

lamp is not lit.

1.  Temperature limit sensor has 

overheated. 

2.  No electrical power. 

3.  Fuse is blown.

4.  Improper electrical connection 

between temperature limit sensor 

and circuit board. 

1.  Push power switch to “OFF and 

allow heater to cool for 10 minutes. 

Restart heater. 

2.  Check power cords for proper 

connection and test the power 

supply.

3.  Check / replace the fuse.

4.  Inspect all electrical connections.

Summary of Contents for SilentDrive REM-150T-SDR-B

Page 1: ...N FOR OUTDOOR USE INDOOR USE PER MITTED ONLY FOR THE TEMPORARY HEATING OF ADEQUATELY VENTILAT ED BUILDINGS OR STRUCTURES UNDER CONSTRUCTION ALTERATION OR REPAIR This is an unvented portable heater tha...

Page 2: ...ed by these instructions Never use the heater in spaces which contain products such as gasoline solvents paint thinners dust particles volatile or airborne combustibles or any unknown chemicals This i...

Page 3: ...buildings under construction altera tion or repair Provide at least a three square foot 2 800 sq cm open ing of outside air for every 100 000 Btu Hr 29 kW heater rating Refer to Ventilation on page 6...

Page 4: ...Pressure PSI BAR 111 7 65 121 8 3 Volts AC Hz 120VAC 60 Hz 120VAC 60 Hz Amps 3 15A 3 15A Phase 1 1 Specifications subject to change without notice Tools Needed Phillips head screw driver 8 mm open en...

Page 5: ...both sides of the tank lip and wheel support frame and tighten firmly 6 Insert 2 short screws 30 mm through the first hole the front of in the tank lip and tighten firmly Make certain all 6 screws are...

Page 6: ...a source of heat NEVER use kerosene that has been stored from one season to the next Kerosene deteriorates over time OLD KEROSENE WILL NOT BURN PROPERLY IN THIS HEATER NOTE Kerosene should only be sto...

Page 7: ...ise increases the pressure Counterclockwise decreases pressure TIP If the heater does not ignite press power button to power off the heater check steps 1 3 above and press power button to power ON the...

Page 8: ...HAVE A COMPETENT SERVICEMAN MAKE ANY NECESSARY ADJUSTMENT OR REPAIRS Use only original equipment parts The use of alternate or third party components can cause unsafe operating conditions and will voi...

Page 9: ...he spark plug clean the terminals with a wire brush Re gap the terminals to 0 140 3 5mm See Figure 7 PHOTOCELL The photocell should be cleaned using a cotton swab dipped in alcohol or water at least o...

Page 10: ...R Brown 6 7 8 9 10 2 6 1 3 11 12 12 BK BK BK BK AC 250V 3 15A BK BL GN RD BR YL BL BL BL BL RD RD 1 Encendedor 2 Bomba del Combustible 3 Motor 4 Condensador 5 Control de Limite 6 El Vertedero 7 Asambl...

Page 11: ...g 8 Defective ignitor 1 Fill tank with fresh kerosene 2 Clean replace spark plug 3 Clean replace fuel filter 4 Clean replace nozzle 5 Rinse fuel tank with clean fresh kerosene 6 Inspect all electrical...

Page 12: ...33 36 EXPLODED VIEW PARTS LIST Item Description 150T SDR 220T SDR 1 Combustion Chamber 70 011 1000 70 011 1010 2 Main Power PCB 70 027 2005 70 027 2005 3 Power PCB Case 70 027 1250 70 027 1250 4 PCB L...

Page 13: ...037 0350 19 Side Cover 70 008 1100 70 008 1100 20 Power Cord 70 034 1000 70 034 1000 21 Return Fuel Line 70 036 0020 70 036 0020 22 Intake Fuel Line 70 036 1010 70 036 1010 23 Fuel Pump 70 400 0110 75...

Page 14: ...item freight pre paid If Pinnacle Climate Technologies Inc finds the item to be in normal operating condition or not defective the item will be returned freight collect This Limited Warranty is in li...

Page 15: ...LES OU DANS DES ESPACES CLOS SANS VENTILATION AD QUATE POUR USAGE EXT RIEUR USAGE INT RIEUR PERMIS SEULEMENT POUR LE CHAUFFAGE TEMPORAIRE DES STRUCTURES OU DES B TIMENTS BIEN VENTIL S EN COURS DE CONS...

Page 16: ...la chaufferette selon les recommandations de ces instructions Ne jamais utiliser la chaufferette dans des endroits qui contiennent des produits comme essence solvants diluants peinture poussi res sub...

Page 17: ...n ou de r paration Fournir une ouverture d au moins 2 800 cm 3 pi sur l air ext rieur pour chaque 29 kWh 100 000 BTU h du r gime nominal de la chaufferette Voir Ventilation la page 6 pour plus de d ta...

Page 18: ...de la pompe PSI BAR 111 7 65 121 8 3 Volts c a Hz 120 V c a 60 Hz 120 V c a 60 Hz Amp res 3 15 A 3 15 A Phase 1 1 Sp cifications sujettes modification sans pr avis Outils n cessaires Tournevis crucif...

Page 19: ...du rebord du r servoir et de l armature du support et serrer fermement 6 Ins rer 2 boulons courts de 30 mm dans le premier trou l avant du rebord du r servoir et serrer fermement S assurer que tous l...

Page 20: ...oximit d une source de chaleur NE JAMAIS utiliser du k ros ne entrepos la saison pr c dente pour la saison suivante Le k ros ne se d t riore avec le temps LE VIEUX K ROS NE NE BR LE PAS CORRECTEMENT D...

Page 21: ...lage de la pompe Tourner la vis en incr ments d un quart de tour Vers la droite pour augmenter la pression Vers la gauche pour diminuer la pression CONSEIL Si l appareil ne s allume pas appuyer sur le...

Page 22: ...ECTU PAR UN TECHNICIEN COMP TENT Utiliser uniquement des pi ces de rechange d origine L utilisation de composants tiers ou de substitution risque de cr er des conditions de fonctionnement dangereuses...

Page 23: ...c une brosse m tallique R gler l cartement des bornes 3 5 mm voir la Figure 7 CELLULE PHOTO LECTRIQUE La cellule photo lectrique doit tre nettoy e l aide d un coton tige tremp dans de l eau ou de l al...

Page 24: ...ow RD Red GN Green BR Brown 6 7 8 9 10 2 6 1 3 11 12 12 BK BK BK BK AC 250V 3 15A BK BL GN RD BR YL BL BL BL BL RD RD 1 Encendedor 2 Bomba del Combustible 3 Motor 4 Condensador 5 Control de Limite 6 E...

Page 25: ...nect s la bougie 8 Allumeur d fectueux 1 Remplir le r servoir de k ros ne neuf 2 Nettoyer remplacer la bougie 3 Nettoyer remplacer le filtre carburant 4 Nettoyer remplacer la buse 5 Rincer le r servoi...

Page 26: ...36 VUE CLAT E LISTE DES PI CES No de r f Description 150T SDR 220T SDR 1 Chambre de combustion 70 011 1000 70 011 1010 2 Circuit d alimentation principal 70 027 2005 70 027 2005 3 Bo tier du circuit...

Page 27: ...0350 70 037 0350 19 Couvercle lat ral 70 008 1100 70 008 1100 20 Cordon lectrique 70 034 1000 70 034 1000 21 Conduite de retour de carburant 70 036 0020 70 036 0020 22 Conduite d arriv e de carburant...

Page 28: ...s il est d fectueux Pinnacle Climate Technologies Inc r parera ou remplacera et retournera l article en port pay Si Pinnacle Climate Technologies Inc d termine que l article est dans un tat d utilisa...

Reviews: