80
EN
Outside temperature The measurement is taken in the boiler and passed to the controller.
Consult the boiler documentation regarding the accuracy of the measurement.
Set temperature range 5 – 35°C
Calibration options Inside and outside temperature sensor: -5 to + 5 in steps of 0.5°C
Control Modulating temperature control
The control can be optimised
Room control Overshoot: maximum 1°C after pre-heating
Temperature variation: less than 0.25°C
Control strategies Room temperature control
Weather-compensated control
4 combination options
Features of the controller
Backlight Colour: blue
Date/time indication Time: 24 h clock. Accuracy: to about 365 seconds per year
Date: day – month – year
Automatic switching to summer time
Programs 2 clock programs with 6 switch points per day
Boiler clock program with 6 switch points per day
16 holiday programs
Day, Night, Frost protection, Summer mode, Fireplace