47
569000203
Trouble
Remedy
Probable Cause
DISPENSED PRODUCT
PRODUCES FOAM AS IT
LEAVES DISPENSING VALVE.
(cont’d)
F.
Dirty water supply.
F.
Check water filter. Replace
cartridge (see
NOTE
).
NOTE: If water supply is dirty, be sure to flush lines and
carbonator carbonated water tank completely. It may be necessary
to remove lines to the carbonated water tank, invert the tank, then
flush tank and all inlet lines to remove any foreign particles or dirt.
NO PRODUCT DISPENSED
FROM ALL DISPENSING
VALVES.
A.
Unit power switch (60-Hz Unit)
in ‘‘OFF’’ position.
A.
Place power switch in ‘‘ON’’
position.
B.
Dispensing valves keyed
lock-out switch in “OFF”
(horizontal) position.
B.
Place dispensing valves keyed
lock-out switch in “ON” (vertical)
position.
C.
No electrical power to Unit.
C.
Plug in Unit power cord or check
for blown power fuse or tripped
circuit breaker. (Note: Fuse or
circuit breaker are not part of
Unit.)
D.
Disconnected dispensing
valves power cord.
D.
Connect dispensing valves power
cord.
E.
Disconnected or broken wiring
to dispensing valve.
E.
Connect or replace wiring.
F.
Inoperative transformer.
F.
Replace transformer.
ONLY CARBONATED WATER
DISPENSED.
A.
Out of syrup
A.
Replenish syrup supply as
instructed.
B.
Inoperable dispensing valve.
B.
Repair dispensing valve.
C.
Dispensing valve syrup flow
control not properly adjusted.
C.
Adjust dispensing valve syrup
flow control (Water-to-Syrup
‘‘Ratio’’) as instructed.
D.
Dispensing valve syrup flow
control or syrup lines
restricted.
D.
Sanitize syrup system as
instructed.
Summary of Contents for Cornelius VANGUARD 245
Page 7: ...2 569000203 THIS PAGE LEFT BLANK INTENTIONALLY ...
Page 29: ...24 569000203 THIS PAGE LEFT BLANK INTENTIONALLY ...
Page 49: ...44 569030007 FIGURE 17 WIRING DIAGRAM DISPENSER P N 497306660WS WHT OR BLU BLK OR BRN ...
Page 55: ...50 569000203 THIS PAGE LEFT BLANK INTENTIONALLY ...
Page 61: ......
Page 68: ......
Page 70: ...63 569000203 THIS PAGE LEFT BLANK INTENTIONALLY ...