18
569000203
8.
Unit With Integral Carbonator–
Place carbonator motor power switch in “ON” position. The Unit integral
carbonator water pump motor will start and begin filling the carbonated water tank when the Unit is put into
operation.The carbonator water pump motor will stop after the water tank has been filled with carbonated
water.
IMPORTANT: Circulating air, required to cool the refrigeration assembly condenser coil, is drawn in
through grille on back of the hood and is exhausted out through grille on top of the hood. For proper
cooling of the condenser coil, the hood back grille must be positioned over the condenser coil on back
side of the Unit.
9. Install hood on the Unit and secure with SCREW (item 11).
PREPARATION FOR OPERATION
Unit (P/N 497306660WS).
Activate the chilled plain water dispensing system (see Figures 2 and 9) as follows:
1. Activate plain water supply to the Unit.
2. Place cup or glass under plain water spout located between No. 5 and No. 6 dispensing valves.
3. Press water dispense switch on side of the drip tray support and dispense until all air is purged from the
chilled plain water system, then release dispense switch.
Activate dispensing valves carbonated water and plain water systems (all Units) as follows:
1. Activate plain water and carbonated water supplies to the Unit.
2. Place dispensing valves keyed lock-out switch on side of the Unit in the ‘‘ON’’ position.
3. Dispense from all dispensing valves to purge all air from the carbonated water and the plain water systems.
4. Check entire system for plain water, carbonated water, and CO
2
leaks and repair any leaks.
IMPORTANT: All syrup systems
must
be sanitized before the Unit is put into operation.
5. Sanitize all syrup systems as instructed in the SERVICE AND MAINTENANCE section of this manual.
6. Activate syrup supplies to the Unit.
7. Dispense from all dispensing valves to purge all air from the syrup systems.
IMPORTANT: Circulating air, required to cool the refrigeration assembly condenser coil, is drawn in
through grille on back of the hood and is exhausted out through grille on top of the hood. For proper
cooling of the condenser coil, the hood back grille must be positioned over the condenser coil on back
side of the Unit.
8. Install hood on the Unit and secure with SCREW (item 11).
NOTE: The dispensing valves adjustable water flow regulators are factory adjusted and should require
no further adjustment. If readjustment should become necessary, refer to SERVICE AND
MAINTENANCE section for the proper adjustment procedure.
9. Adjusting Dispensing Valves For Water-To-Syrup “Ratio” (Brix) Of Dispensed Product.
The dispensing valves are each equipped with adjustable syrup flow regulators. The Water-To-Syrup
“Ratio” (Brix) of the dispensed product is controlled by adjustment of these syrup flow regulators. Refer to
SERVICE AND MAINTENANCE section for the adjustment procedure.
10. Re-check entire installation for CO
2,
plain water, carbonated water, and syrup leaks and repair any leaks.
Summary of Contents for Cornelius VANGUARD 245
Page 7: ...2 569000203 THIS PAGE LEFT BLANK INTENTIONALLY ...
Page 29: ...24 569000203 THIS PAGE LEFT BLANK INTENTIONALLY ...
Page 49: ...44 569030007 FIGURE 17 WIRING DIAGRAM DISPENSER P N 497306660WS WHT OR BLU BLK OR BRN ...
Page 55: ...50 569000203 THIS PAGE LEFT BLANK INTENTIONALLY ...
Page 61: ......
Page 68: ......
Page 70: ...63 569000203 THIS PAGE LEFT BLANK INTENTIONALLY ...