14
569000203
1. Route the carbonated water source line from the carbonated water source location up to the Unit.
2. Connect the carbonated water source line to the desired labeled stainless-steel water inlet tubes on front of
the Unit.
CONNECTING PLAIN WATER SOURCE LINES TO UNIT
NOTE: Cornelius Inc; recommends that a water shutoff valve and a water filter be installed in the
plain water source to be connected to the Unit. The plain water source water pressure must not be less
than 35-psi or more than 45-psi. If water pressure exceeds 45-psi, a water pressure regulator must be
used to regulate the water pressure.
The plain water source to the equipment shall be installed with adequate back flow protection to
comply with applicable Federal, State, and local codes.
NOTE: No. 1 dispensing valve is the valve on the left side facing front side of the Unit.
UNIT REQUIRING CONNECTION TO REMOTE CARBONATOR
(see applicable Figure 2, 3, or 4)
Proceed as follows to connect plain water source line to No. 3 (six-flavor Unit) or No. 4 (eight-flavor Unit) dispensing
valve on Unit requiring connection to a remote carbonator.
1. Route plain water source line from plain water source up to the Unit.
2. Connect plain water source line to barbed stainless-steel plain water inlet tube labeled “WTR 3” (six-flavor
Unit) or “WTR 4” (eight-flavor Unit) on front of the Unit.
UNIT WITH INTEGRAL (BUILT-IN) CARBONATOR
(see applicable Figure 5 or 6)
Proceed as follows to connect plain water source line to Unit with an integral (built-in) carbonator.
1. Route plain water source line from plain water source up to the Unit.
2. Connect plain water source line to barbed stainless–steel plain water inlet tubes for No. 3 and 4 (six–flavor Unit)
dispensing valves or No. 4 and 5 (eight–flavor Unit) dispensing valves.
CONNECTING PLAIN WATER SOURCE LINE TO DESIRED DISPENSING VALVES
(see applicable Figure 2, 3, 4, 5, or 6 and applicable Figure 9, 10, or 11)
1. Route plain water source line from plain water source up to the Unit.
2. Connect the plain water source line to the desired labeled stainless-steel water inlet tube(s) on front of the
Unit.
Summary of Contents for Cornelius VANGUARD 245
Page 7: ...2 569000203 THIS PAGE LEFT BLANK INTENTIONALLY ...
Page 29: ...24 569000203 THIS PAGE LEFT BLANK INTENTIONALLY ...
Page 49: ...44 569030007 FIGURE 17 WIRING DIAGRAM DISPENSER P N 497306660WS WHT OR BLU BLK OR BRN ...
Page 55: ...50 569000203 THIS PAGE LEFT BLANK INTENTIONALLY ...
Page 61: ......
Page 68: ......
Page 70: ...63 569000203 THIS PAGE LEFT BLANK INTENTIONALLY ...