Pressure reducing

valve

312 / 315.5

Spare parts

Instructions for use

What to do......

if the downstream pressure

 rises above the set pressure

in the case of a pressure reducing valve installed for the
purpose of reducing pressure in a hot water system, the
cause is very often due to pressure crossflow in a mixing
valve, due to the fact that the cold water supply has not
been fitted with a pressure reducer.
This occurs especially in the case of thermostatic mixing
valves, single-lever mixing valves or normal two-tap mixing
valves with clogged anti-splash nozzles.
Such faults can only be eliminated by installing the
pressure reducing valve in the main supply line, thus
reducing the pressure in both, the hot and cold water
supply systems to the same level.

R.W.C. Reliance Water Controls LTD.

Worcester Road, Evesham, WR11 4RA

England

Tel.:0386/47148+9  Fax.: 47028  Tx.:339717

0312.15.900 0,5-5,0 bar
0312.20.901 0,5-2,1 bar
0312.20.902 2,1-6,0 bar

0828.08.000

312

315.5

As an option a PRV 315.5 with
incorporated check-valve is
available.
This to protect up-stream
installations against pollution or /
and back pressure.