background image

START TO MASSAGE

Press the button

         

on the handheld remote controller, you can see the 

communication testing interface and the testing function start, if the handheld 
remote controller communicate well with the controller of the massage bed, and the 
handheld remote controller will display the test was successful and change to 
massage interface (and the default model is automatic 1;Vibration massage on ,with 
2 levels), or else display the test was failed and presents the message

Standby  

Connected

Communication Test 

OK

Communication 
Testing... 

connection testing

Communication Test 

Communication 
Testing... 

Unconnected

Communication Test 

Communication 
Testing... 

ERROR

Warning

Communication 

ERROR

Please  check if 
the main power 
is turned on or
not.

THE ADJUSTMENT OF THE ANGLE BETWEEN BACKREST AND CALF-REST OF BED BASE

1) Adjust the degree of the backrest

Back up button: press this button when turn on the power, the back will up 

gradually, with dripping sound at the same time. (During two minutes this button 
not touched or mattress go to the top position, the power will be off automatically.). 
Press this button again to stop it.

Back down button: press this button when turn on the power, the back will drop 

gradually, with dripping sound at the same time. (If it was no reaction within two 
minutes, then you can press this button again to turn it off). Press this button 
again to stop it.

Name   Button   Massage Content            

Massage Features   

Display

M

a

s

s

a

g

e

 m

o

d

e

l

Auto 1

Auto 2

Auto 3

AIR MODE

Auto 

AUTO

AUTO

AUTO

AIR MODE

Auto 

AIR MODE

Auto 

AIR MODE

AIR MODE

AIR MODE

AUTO

Auto 4

Auto 

START TO MASSAGE

AUTO

WAIST 

STRETCH

Waist 

Stretch

Auto 5

Auto 

1. Plug in the machine 

instruction manual

Step1

Step2

Step3

Figure : Connecting the power 
configuration of the mattress

Attention

1.Connecting the power, two sides of power line docking port should arrow 
   aligned, slight enforce, or hard plug will damage the inside needle.
2.Be sure not to switch adaptor power unless you finish all the steps above, 
   otherwise you will cause damage to the machine

2.Massage

Massage focus on whole body air pressure, loosens 
the limbs (Advice lay on bed and flat on back 
massage)

This model is to remove the neck massage function 
in Auto 1. (Advice lay on bed and flat on back

Massage focus on neck and shoulder, buttock, 
improve the fatigue symptoms. (Advice lay on bed)

This model is to remove the neck massage function 
in Auto 3. (Advice lay on bed and flat on back 
massage)

Massage focus on belly, promote the gastrointestinal 
function. (Advice lying face up on a bed)

Massage focus on push waist to alleviate the pain 
on the waist.(Advice lay on bed and flat on back 
massage)

Waist 

Stretch

vibration 

switch

Switch on, foot Vibration massage.

Vibration 

intensity

With 3 levels adjustable 

Vibration 

massage 

V

ib

ra

tio

n

 m

o

d

e

l

Figure : Connecting the 
power of the mattress 

The card 

slotretainingring

Aimed at the 

card slot point

After docking, the retaining ring must 

be across thecard slot point

making a sound

then fixed interface.