Parameterization
TR-Electronic GmbH 2013, All Rights Reserved
Printed in the Federal Republic of Germany
Page 118 of 175
TR - ECE - BA - DGB - 0102 - 09
01/17/2019
7.3 Object 0x04, Assembly
The
IO Assembly Object
returns the cyclic output data of the measuring system.
About the
Configuration Assembly
the most important attributes can get
parameterized very simple and fast.
Only a static configuration is supported (
Static Assembly
). Therefore, the number
of
the instances and attributes are defined fix and can’t be changed.
7.3.1 Common Services
Service Code
Service Name
Description
0x0E
Get_Attribute_Single
Returns the contents of the specified
attribute.
7.3.2 Class Attributes
No. Access
Name
Data type
Attribute Description
Default
1
Get
Revision
UINT
Revision of this object
0x0002
2
Get
Max Instance UINT
Maximum instance number of an
object currently created in this class
level of the device.
0x0096
3
Get
Number of
Instances
UINT
Number of object instances currently
created at this class level of the
device.
0x0007
4
-
-
-
not implemented
-
5
-
-
-
not implemented
-
6
Get
Maximum
ID Number
Class
Attributes
UINT
The attribute ID number of the last
class attribute of the class definition
implemented in the device.
0x0007
7
Get
Maximum ID
Number
Instance
Attributes
UINT
The attribute ID number of the last
instance attribute of the class definition
implemented in the device.
0x0003
Table 11: Assembly, Overview of the class attributes