Attach a suitable lifting strap to the heater tube at the two lifting eye bolts in the heater flange. Remove all
of the slack from the lifting strap so as to provide support for the heater as it is unbolted from the heater
vessel flange, but taking care not to apply excess tension. Remove the flange studs and nuts from the
heater that secure it to the heater vessel. Once the heater bundle is free from the heater vessel, remove it
and set aside.
Inspect the heater for coking and for cracked or split elements. Clean the heater bundle to remove any
residue or contamination that may have entered the heater vessel.
Inspect the interior of the heater vessel and wipe clean with a lint free cloth.
NOTICE:
When removing the oil heater bundle from the
heater vessel, the end of the vessel will be open.
Care should be taken to avoid, minimize and
control oil spills.
Consult with your lubricating oil supplier and the
lubricating oil MSDS documentation regarding safe
guards and Personal Protective Equipment (PPE)
requirements.
See the sections of this manual titled
Cleaning and
Decontamination, Removal from Use, Disposal
and Transport
and
Draining and Cleaning
Procedures
for additional information
Take care to guard against pinching and crushing
hazards when handling the heater bundle.
Inspect and clean the
interior of the heater
vessel