THERMOJET
®
H-2500E SERIES
OIL PURIFIER SYSTEM
INSTALLATION AND OPERATING MANUAL
Doc #
77740119
Rev
15
Date
June 2020
Page
27
of
100
Start-Up Procedures
Before each start-up, perform a “walk-around” of the purifier installation noting if the points covered in
INSTALLATION Section
of this manual are correct.
Ensure that the oil filter element is installed in the filter housing and that the O-ring is in good condition.
Open the oil supply block valve at the serviced oil reservoir.
Use the block valve on the bottom of the reservoir to drain any free water which may have accumulated.
Care should be taken to avoid spills and ground contamination with the drained waste.
Avoid inputting free water from the serviced reservoir
from being input into the ThermoJet Oil Purifier. Free
water will flash to steam when introduced into the
heater, creating sudden surges in system pressure.
DRAIN ALL FREE WATER FROM THE SEVICED
RESERVOIR
NOTICE:
When cleaning oil spills consult with your
lubricating oil supplier and the lubricating oil MSDS
documentation regarding safe guards and
Personal Protective Equipment (PPE)
requirements
In case of oil spillage, the user or other responsible
body must ensure appropriate cleanup and
decontamination is carried out.