![RelaDyne THERMOJET G3000E Series Installation And Operating Manual Download Page 87](http://html1.mh-extra.com/html/reladyne/thermojet-g3000e-series/thermojet-g3000e-series_installation-and-operating-manual_1435630087.webp)
THERMOJET
®
G3000E SERIES
OIL PURIFIER SYSTEM
INSTALLATION AND OPERATING MANUAL
Doc #
77740122
Rev
14
Date
JUNE 2020
Page
87
of
104
PID Symbol Legend and Customer Connection Chart
CHECK VALVE
PRESSURE CONTROL VALVE
PRESS. RELIEF VALVE
JET MIXER
SYMBOL LEGEND
OIL TUBING
OIL PIPING
COUPLING
PUMP
OIL LEVEL CONTROL VALVE
*
SIGHT FLOW INDICATOR
Y-STRAINER
CUSTOMER CONNECTIONS CHART
CONN.
QTY
DESCRIPTION
TYPE / RATING
A
1
OIL SUPPLY INLET
1" FNPT
B
1
OIL RETURN OUTLET
1" FNPT
C
1
NITROGEN SUPPLY INLET
3/8" FNPT
D
1
SAFETY RELIEF OUTLET
1" FNPT
E
1
VENT TO FLARE OUTLET
3/4" FNPT
F
1
PAN DRAIN
3/4" FNPT,
G
1
CONDENSATE DRAIN
1/2" FNPT
EA
1
GROUNDING LUG
14 - 1/0 AWG WIRE SIZE