THERMOJET
®
G3000E SERIES
OIL PURIFIER SYSTEM
INSTALLATION AND OPERATING MANUAL
Doc #
77740122
Rev
14
Date
JUNE 2020
Page
54
of
104
Separation Vessel Maintenance
The ThermoJet Oil Purifier must be shut down before performing separation vessel. This maintenance
operation involves removing the separation inspection cover plate and cleaning the interior of the separation
vessel. The inspection cover plate is located on the interior of the ThermoJet Model G3000E console cabinet.
First shut down the ThermoJet. See the section titled
Shut Down Procedures
on how to turn the ThermoJet
Oil Purifier OFF.
Close and tag the nearest oil block valve to the ThermoJet oil inlet and outlet connection.
First drain all oil from the separation vessel and the inlet oil filter. A drain plug is located in the outlet pump
suction line between the separation vessel outlet and the pump suction for draining the separation vessel.
Use the drain valve located at the bottom of the inlet oil filter vessel for draining the oil filter. For additional
information on draining the oil from the oil filter see the section in this manual titled
Oil Filter Maintenance
.Use a pail to gather the oil. See the sections of this manual titled
Cleaning and Decontamination
and
Removal from Use, Disposal and Transport
for additional information.
WARNING
Surfaces and contents are HOT. Once the
system has been shut down allow sufficient time
for cooling before servicing this equipment.
Oil filter drain valve
Clean out cover
Separation drain plug