14
Touch
Screen
User
'
s
Manual
Restart Setup
a. Power Restart
Check the “Power Restart” box if you want the system to automatically restart once an acceptable
voltage is re-obtained.
A. “Last Known Status” the system will restart to its last known status.
B. “Run Start Seq at Power Up”
Note
:
After
7
days
of
no
activity
this
will
no
longer
work
and
will
have
to
be
re-selected.
(see
start
tab)
C. “Restart Delay” is entered in seconds for the length of time which the voltage must
remain between the high and low set points before it will try to restart. Both the high and
low set points need to be entered.
b. Pressure Start
Check “Pressure Start” to start the system once the pressure switch closes or the transducer reaches
a safe value. If using pressure transducer enter the PSI at which the system can restart. Then select
an option from the popup menu for the start up procedure to follow.
Note
:
If
using
pressure
switch
the
system
will
execute
the
selected
function
once
the
switch
sees
pressure.
c. Voltage Settings
Low Voltage: Set this voltage to the minimum allowable voltage for normal system operation.
High Voltage: Set this voltage to the maximum allowable voltage for normal system operation.
Voltage Scale: Controls input voltage. If voltage reads 470 but is actually 480 enter 1.02 to
calibrate closer to the actual voltage on system.
Voltage Offset: Enter either a negative or positive number to offset what the actual voltage coming
in to what is shown.
d. Voltage Selection Radial Buttons
Select the voltage and frequency that best fits the available power supply. If you are unsure which is
correct please contact your dealer before changing this setting.
e. Wait Prss
If “Wait Prss” is selected for pressure start, the pump will remain energized all of the time and the
pressure input will start/stop the system.
a.
b.
c.
d.
e.
3. Power/Pressure Restart Settings:
W
arnin
g
:
I
f po
w
er restart is c
h
ec
k
ed it is possi
b
le for t
h
e system to restart on it’s o
w
n if t
h
e
main po
w
er supply is in t
h
e ON position, ensure
wh
en auto
-
restart is not desired s
h
ut main
po
w
er supply OFF.
WITH TOUCH TECHNOLOGY