Pump Setup
12
Touch
Screen
User
'
s
Manual
2. Main Water Pump Settings:
a.
a.
b.
c.
d.
a. Depth @100%(IN.)
For “Depth” enter the depth of water applied by the system while running at 100%. Again see
system chart in panel. (Shown below)
b. Pressure Sensor
On the “Pressure Sensor” drop down menu select the pressure device installed: None, Switch,
Transducer (0-200, Transducer (0-25) or EOS Transducer (0-200)
1. If Switch is selected only the scale and shutdown delay will be shown.
A. “Scale” controls input voltage. For instance, a 1 to 2 scale would make 5V into 10V.
B. In “Shutdown Delay”, enter the time in seconds to delay a pressure shutdown in order to
reduce nuisance shutdowns. If the system suddenly loses pressure and goes below the set
pressure, this time will allow the system to continue to run for set time allowing the pressure
to rebuild.
C. “Shutdown Pressure” should be set according to the type of pressure transducer selected.
c. Pump Delay Build
In “Pump Delay Build” enter the number of seconds to allow the pump to operate to build up
pressure. When the pump is started or restarted by automatic restart, the pump will be allowed to
operate for this amount of time in seconds to build up pressure. The computer will then check to see
if the pressure is above the minimum water pressure before it will start or restart the system.
d. Pump Delay Restart
“Pump Delay Re-Start” entered in seconds, so if the pressure switch does not close or the pressure
transducer does not reach minimum pressure during the pressure build up delay, the pump will shut
down and wait.. This allows the well time to settle before allowing the pump to be restarted.
.
WITH TOUCH TECHNOLOGY