8.2.2 Querying parameters of the Microprocessor
Call the current data file:
'?' 'U' <#13>
Read out stored data from address 00H and following
'?' 'Y' <#13>
Read out stored data at a certain time:
'?' 'D' <TIME DATE in Format HHMMSSDDMMYY> <#13>
CAUTION: All firmware version inclusive 2.39 cancel the search of data in the logger when a full
hour is reached. Also sending data out of the logger is cancel at each full hour. This problem is
caused by searching a GPS receiver at the GPS input each hour.
This problem was solved with firmware version 2.40.
Also see the FAQs to the 32bit software on the "WETTER CD"
Call all the stored data:
'?' 'D' '000000000000' <#13>
Interrupt the data output :
<#13>
Continue the data output after the moment of interrupt:
'!' 'C' <#13>
Call linearisation data, sensor configuration and system information:
'!' '?' <#13>
Since µP Version 2.39 the command !? can be combinedwith a sensor-number, i.e.:
'!' '?0' <#13>
Only the info about the main configuration will be sent.
'!' '?1' <#13>
Only the info about the configuration of the sensors will be sent.
'!' '?2' <#13>
Only the info about the sensor 2 (temperature) will be sent.