Manual MWS 6
If you have chosen a 5 minutes memory interval (288 data files / day), you can store
more than 38 days in the data logger, if you have 4 RAMs with 8 sensors.
Data logger and time are still there if the POWER-connector is plugged in, but no
more data are recorded. Current consumption is about 200
µ
A then which grants a
data buffer up to 150 days. The internal batteries will be exhausted then and must
be changed.
If you remove the power connector, the data logger is emptied and the clock is
deleted.
If the mains supply is removed, the data collector works as if there had been a power
failure and uses the internal buffer batteries.
Please note that with a plugged-in power connector and plugged-off mains supply,
the internal buffer batteries are discharged!