PCset graphic Hilfe jetStamp 1025
74
© ERNST REINER GmbH & Co. KG
Originalanleitung
7.2
Causes for uncharged batteries
- No batteries inserted or batteries inserted incorrectly
- Incorrect contact in battery compartment
- Battery temperature above 54 degrees Celsius
- Batteries outdated
- Batteries defective
- Batteries completely discharged (deep discharge)
Capacity and service life
The batteries reach their full capacity after several discharges and recharges. With increasing aging
of the batteries, the possible operating time shortens.
Rechargeable batteries are subject to wear. A longer service life than six months cannot be
guaranteed.
7.3
Warning messages
Message
Eliminate message
by
Remark
Print cartridge almost
empty
Confirm. Reappears the
next time the device is
switched on.
The print cartridge is almost empty and will
have to be replaced soon.
Rechargeable battery
almost empty
Confirm. Reappears the
next time the device is
switched on.
The rechargeable battery is almost empty.
Please connect the device to the power
supply to charge the battery.
Transmission
interrupted
Confirm
The print image was not transferred. The
data transfer between PC and device was
interrupted.
Print carriage
movement blocked
Confirm
The print carriage movement has blocked.
Possibly due to an obstacle or heavy
soiling.