9
PORTA
GANTRY
500-3000
ATEX
This product has been designed for use in
explosive atmospheres in line with the following
requirements and information. Any use which
differs or exceeds this is considered incorrect
and REID Lifting Ltd will not accept any
responsibility or liability for damages resulting
from false application. The risk is solely with the
user. If the product has been customised in
any way, then it may not comply with standards
and no longer be suitable for use in explosive
atmospheres. If this is the case, then the product
will not have any of the markings below. If in
doubt, please contact your REID representative.
Classification [Zone 2]
As standard, the product meets the requirements
of Category 3 equipment for use in Zone 2
explosive atmospheres, providing a normal level
of protection where mixtures of air and gases,
vapours or mists or by air and dusts mixtures are
unlikely to occur or, if they do occur, are likely
to do so only infrequently and for a short period
only.
The product will have the following identification
on the serial label:
As Standard for Zone 2 Environments:
II 3 GD T6
Identification for protection against explosions
II: Unit group II – non-mining application
3: Category 3 – Normal safety for use in Zone 2
GD: For use in gas (G) & dust (D) atmospheres
T6: Temperature class – Max 85°C
Classification [Zone 1]
Available as an upgrade, the product can
be supplied to meet the requirements of
Category 2 equipment for use in Zone 1
explosive atmospheres, providing a high level
of protection where mixtures of air and gases,
vapours, mists or by air and dusts mixtures are
likely to occur.
The product will have the following identification
on the serial label:
As an Upgrade for use in Zone 1 Environments:
II 2 GD T6
Identification for protection against explosions
II: Unit group II – non-mining application
2: Category 2 – High safety for use in Zone 1
GD: For use in gas (G) & dust (D) atmospheres
T6: Temperature class – Max 85°C