PAGE 27
Error-No. Level
Description
Cause
Troubleshooting
4013
13
Invalid resume switch state
with Kubota M7
invalid resume switch state
- check cables from GREEN FIT con-
troller to M7 VCU2.
- check resume switch
4020
21
Braud – Field / Road Switch
status road is active
engage field status
4021
21
No communciation to Braud
no sensor readings
contact Reichhardt support
4022
21
No communciation to Braud
no speed readings
contact Reichhardt support
4023
21
No communciation to Braud
no safety switch readings
contact Reichhardt support
4024
21
No communciation to Braud
no switch field/road switch rea
-
dings
contact Reichhardt support
4030
21
Oxbo 8840 – communication
error
no sensor readings
contact Reichhardt support
4031
21
Oxbo 8840 – System locked
system is locked by vehicle
unlock system by vehicle
4032
21
Oxbo 8840 – communication
error
no safety flags readings
contact Reichhardt support
4033
21
Oxbo 8840 – communication
error
no status readings
contact Reichhardt support
4034
21
Oxbo 8840 – No communi
-
cation
no connection to vehicle
check CAN bus connection
9000
22
invalid Hardware
the hardware used is not compati-
ble for this software
contact Reichhardt support
9001
22
terminal Version is too old
software update from GREEN FIT
Controllers
update the terminal with the latest
software version available
9002
22
No steering mode is selected
- There is no steering mode se-
lected.
- A time limited license has ex-
pired.
- Select a steering mode.
- contact Reichhardt support
9050
22
battery power lost before sys-
tem shut down completely
- battery / switched power wiring
not correct
- software issues
- system has no battery power or pro-
per switch
- contact Reichhardt support
9060
22
field/road switch
-
Not in field position
- Switch is defective
check switch position
9100
29
EEPROM write error
- EEPROM is defective
- EEPROM is busy
contact Reichhardt support
9101
29
EEPROM read error
- EEPROM is defective
- EEPROM is busy
contact Reichhardt support
9102
29
check EEPROM data
older software is updated
check all parameters and settings
9103
29
EEPROM values changed
automatically
after software update it is some-
times necessary to set parameters
to default
check parameters
9104
29
EEPROM value(s) out of range
a parameter was out of range and
set to default
contact Reichhardt support
9105
29
vehicle offsets not taught
after software update new vehicle
offsets need to be taught
teach vehicle offsets
9106
29
EEPROM to small
EEPROM is too small for software
contact Reichhardt support
9107
29
EEPROM read error
Data is to be stored while it is being
read
contact Reichhardt support
9108
29
EEPROM write error
Data is to be read while it is being
written.
contact Reichhardt support