PAGE 23
Error-No. Level
Description
Cause
Troubleshooting
1356
23
no speed information from
"NMEA_2000"
no NMEA_2000 speed information
available
change setting of speed signal source
1357
23
speed is out of range
- speed is too slow
- speed is too fast
- speed up
- reduce speed
1358
23
speed – configuration invalid
CAN bus 2 can not used
- Select CAN bus 1
1500
5
Lock valve left – open wire
- Lock valve is defective.
- Open wire in cable.
- Contacts of connectors are ope-
ned.
- Inspect lock valve.
- Check cables from GREEN FIT Con-
troller to lock valve.
- Check contacts of connectors.
1501
5
Lock valve left – short circuit
- Lock valve is defective.
- Short circuit in cable.
- Contacts of connectors are clo-
sed.
- Inspect lock valve.
- Check cables from GREEN FIT Con-
troller to lock valve.
- Check contacts of connectors.
1502
5
Lock valve right – open wire
- Lock valve is defective.
- Open wire in cable.
- Contacts of connectors are ope-
ned.
- Inspect lock valve.
- Check cables from GREEN FIT Con-
troller to lock valve.
- Check contacts of connectors.
1503
5
Lock valve right – short circuit
- Lock valve is defective.
- Short circuit in cable.
- Contacts of connectors are clo-
sed.
- Inspect lock valve.
- Check cables from GREEN FIT Con-
troller to lock valve.
- Check contacts of connectors.
1550
4
Steer valve – left open wire
- Steer valve is defective.
- Open wire in cable.
- Contacts of connectors are ope-
ned.
- Inspect steer valve .
- Check cables from GREEN FIT Con-
troller to steer valve.
- Check contacts of connectors.
1551
4
Steer valve – left short circuit
- Steer valve is defective.
- Short circuit in cable.
- Contacts of connectors are clo-
sed.
- Inspect steer valve.
- Check cables from GREEN FIT Con-
troller to steer valve.
- check contacts of connectors.
1552
4
Steer valve – right open wire
- Steer valve is defective.
- Open wire in cable.
- Contacts of connectors are ope-
ned.
- Inspect steer valve.
- Check cables from GREEN FIT Con-
troller to steer valve.
- Check contacts of connectors.
1553
4
Steer valve – right short circuit
- Steer valve is defective.
- Short circuit in cable.
- Contacts of connectors are clo-
sed.
- Inspect steer valve.
- Check cables from GREEN FIT Con-
troller to steer valve.
- Check contacts of connectors.
1555
6
Steer valve – lockout active
(PVED-CLS)
Any condition on vehicle side is
not ok.
-
Check vehicle specific feature.
- All states in work mode.
1710
8
no power at relay input side
- fuse defective
- power supply is not switched on
- check fuses to GREEN FIT Controller
and at power input
- check power is switch on