46
A3 Maintenance
A) At least once a year please have your Move-
Control maintained and visually inspected as
described below:
- Cleaning of the complete drive unit.
- Application of suitable lubricant to all moving
parts (e.g. silicon spray).
- Check of the distance between the drive
rollers and the tyres as well as a checking the
tyre pressure.
- Visual inspection for damage of the cables
and the electrical connections.
- Check battery voltage.
- The threads at the spindles are regularly, at
least once a year before putting into operation,
treat with a suitable lubricant and checked for
easy going.
B) Before moving please check if the moving
drive is free of dirt, sand and debris.
C) In case of failures or problems please contact
your supplier.
Appendix
A1 Synchronization
Following a malfunction or after exchanging an
electronic part a synchronization procedure must
be carried out. Proceed as follows and avoid
pauses of more than 2 seconds:
Turn ON handset = Double click
E-box reset-button = push
LED E-box Off
Turn OFF handset = single click
The reset process is complete.
Attention!
If the LED does not go out after
repeating reset procedure for several times,
please contact your dealer.
The synchronization is completed.
Attention! Avoid pauses of more than 2 sec-
onds during the synchronization, otherwise
the synchronisation has to be restarted.
After approx. 20 seconds, the remote control will
be switched-off automatically, if there were no
entries!
If necessary turn the remote control
OFF = push
System ON = turn isolation switch on
E-box reset-button = push and hold!
Handset turn ON = Double click
LED remote control
LED E-box
Handset turn OFF = push
LED remote control
LED E-box
Release reset-button
Off
On
Execute the next steps for the master E-box and
repeat the procedure for the slave E-box and the
same remote control after that!
A2 Reset
The reset process is only required if the LED of
the E-boxes shines. This is an error signal (for
example overload) - the LED is usually off.
When resetting the overload protection reverts to
its normal position.
This procedure is to be executed first for the mas-
ter E-box and after that for the slave E-box.
4@.$UXJO@.#"
4@.$UXJO@.#"
Summary of Contents for 527-0541
Page 3: ...f 3 Montage Twin Installatie Twin Installation Twin Montage Twin e 4 UXJO 4 UXJO...
Page 22: ...22 4 UXJO 4 UXJO...
Page 36: ...36 4 UXJO 4 UXJO...
Page 50: ...50 4 UXJO 4 UXJO...
Page 64: ...64 4 UXJO 4 UXJO...
Page 65: ...65 4 UXJO 4 UXJO...
Page 66: ...66 4 UXJO 4 UXJO...