FEATURES OF THE CPM
REI
CPM-700
10
The remaining functions in this group are active only while in the
MONITOR
mode:
SILENT/TONE (5): Silences the audible beeper during an
ALERT. The LED will continue to flash.
Display shows whether
CPM is in
TONE
or
SILENT mode.
THRESHOLD (6): Moves a pulsing segment to any position on the LCD Bar
graph. When the input level exceeds the pulsing segment, the CPM-700
enters an Alert Mode and activates the Remote Output.
The THRESHOLD control is active only in the MONITOR mode.
ALERT (7): LED flashes red while in ALERT mode.
DISPLAY GROUP
INPUT LEVEL (8): Bar graph indicates signal strength of Probe or Auxiliary
Inputs; compressed semi-logarithmic with two sensitivity scales.
PULSING SEGMENT (9): In MONITOR mode only, displays the Threshold
Point that will activate the Alert mode and Remote Output.
LOW BATT (not shown): Battery voltage indicator; indicates approximately
10% remaining power.
STATUS DISPLAY (10): Shows unit operating conditions made by switch
selections and input used.
NOTE: This status display figure is used in this manual to help you verify
the current setup. Only one label per block appears at any one time on the
actual display, depending on the switch settings
.