Fault
48
Arc has a strange colour
Cause:
Remedy:
No or too little protective gas
Check
Electrode dirty
Grind
Electrode burns off
Cause:
Remedy:
No protective gas
Check
Current load too high
Use a thicker electrode
Pulse share too high with AC current welding
Increase the negative share using balance
Connection between the torch and the grounding
cable reversed
Connect correctly
Electrode welding is set
Set TIG welding
System does not pulse
Cause:
Remedy:
Pulse is not switched on
Set pulse time T1 and / or T2
Values for T1 and T2 are equal
Change the values
Arc breaks away on ignition
Cause:
Remedy:
Ignition energy set too low
Set the ignition energy or use
thinner electrodes
Electrode is consumed or dirty
Grind electrode