Technical data
54
180 DC
230 DC
180 AC/DC
230 AC/DC
Protection class
without water cooling
2
2
2
2
with water cooling
1
1
1
1
Insulation class *
3
F
F
F
F
EMV emissions class
A
A
A
A
Cooling type
AF
AF
AF
AF
Overvoltage category
III
III
III
III
Torch cooling
without water cooling
Gas
Gas
Gas
Gas
with water cooling
Water
Water
Water
Water
Noise emission *
4
< 70dB(A)
< 70dB(A)
< 70dB(A)
< 70dB(A)
Maximum protective gas
pressure
6 Bar
(87.02 psi)
6 Bar
(87.02 psi)
6 Bar
(87.02 psi)
6 Bar
(87.02 psi)
Dimensions L x B x H
without water cooling
480x160x320 mm
480x160x320 mm
480x160x320 mm
480x160x320 mm
with water cooling
480x215x530 mm
480x215x530 mm
480x215x530 mm
480x215x530 mm
Weight (without coolant)
without water cooling
7.1 kg
7.5 kg
7.3 kg
7.9 kg
with water cooling
15.6 kg
16.0 kg
15.8 kg
16.4 kg
Standards
60974-1
60974-2
60974-9
60974-10
CE
60974-1
60974-2
60974-9
60974-10
CE
60974-1
60974-2
60974-9
60974-10
CE
60974-1
60974-2
60974-9
60974-10
CE
Water cooling
Cooling power
at 1 l/min (25°C)
600 W
at 1 l/min (40°C)
330 W
Max (25°C)
1000 W
Max (40°C)
500 W
Maximum flow rate
2,5 l/min
Maximum pump
pressure
4.0 Bar
58.0 psi
EMC protection class
A
Tank content
1.5 l
Pump
Centrifugal pump
Monitoring flow
Error message
below 0.5 l/min
Monitoring coolant
Error message
above 65°C
Fuse
10 A slow-blow
Summary of Contents for TIGER 180 AC/DC ULTRA
Page 6: ...Introduction 6 1 2 General description Fig 1 TIGER Fig 2 TIGER with integrated Water cooling ...
Page 58: ...Circuit diagram 58 11 Circuit diagrams Circuit diagram TIGER 230 AC DC ...
Page 59: ...Circuit diagram 59 Circuit diagram TIGER 230 AC ...
Page 60: ...Circuit diagram 60 Circuit diagram TIGER 180 AC DC ...
Page 61: ...Circuit diagram 61 Circuit diagram TIGER 180 DC ...
Page 63: ...Circuit diagram 63 Circuit diagram TIGER water cooling unit ...
Page 67: ......