Trouble-Shooting Table
35
7.2 Troubleshooting Table
Control lamp MAINS ON (green) has gone out
–
not working
Cause
Remedy
Mains or phase voltage missing
Check fuses and voltages
Fault in mains cable or plug
Check these
Equipment will not switch on
–
control lamp OPERATION (green) has gone out
Cause
Remedy
Operation blocked by one of the yellow
See “Control lamps”
control lamps
Faulty torch button or hose bundle
Service required!
Torch not properly assembled after
Check this
replacement of wear parts
Control lamp OPERATION (green) is on steadily
Cause
Remedy
Torch button faulty (short-circuit)
Check torch button
Control defective
Service required!
Control lamp TORCH (yellow) is lit
Cause
Remedy
Torch parts are worn
Change wear parts
Control lamp TEMPERATURE (yellow) is lit
Cause
Remedy
Maximum duty cycle exceeded
Allow equipment to cool down, and clean it if
necessary
The air inlet or air outlet is clogged or
Clean, make sure air can circulate freely,
blocked
if necessary fit air filter attachment
Control lamp AIR PRESSURE (yellow) is lit
Cause
Remedy
Air pressure too low
Provide the required air pressure
WATER control lamp (yellow) is lit (only with water cooling option)
Cause
Remedy
Water pressure too low, not enough water
Replenish water
Water pump fuse has blown
Check fuse and replace if appropriate
Water pump defective
Service required!
Summary of Contents for BARRACUDA RTC 100
Page 1: ...BARRACUDA RTC 60 100 150 OPERATING INSTRUCTIONS Plasma arc cutting GB...
Page 7: ...Introduction 7 1 2 General Description Fig 1 BARRACUDA...
Page 40: ...Circuit Diagrams 40 9 Circuit diagrams...
Page 41: ...Circuit Diagrams 41...
Page 42: ...Circuit Diagrams 42...
Page 45: ...List of Components 45 1 2 3 6 7 4 8 9 10 11 12 13 14 15 42 16 39 17 20 22 5...
Page 46: ...List of Components 46 38 23 24 25 26 27 60 28 29 30 31 34 E Box 33 35 36 37 32 40 F3 F5...
Page 50: ...Mechanised Interlocks 50 11 4 Connection schematic for A pole mechanised cutting interface...
Page 55: ...by REHM Printed in Germany No 730 1200 06 2013 GB...