Accessories
17
3.2.4
Operating modes
3.2.4.1
2-step function sequence
Step 1 - Press torch button
Gas pre-flow time 4 seconds.
Pilot arc is ignited.
On contact with work piece, the cutting arc is ignited and the compressed air
is increased to the required throughput rate.
If contact is not made with the work piece within four seconds, the equipment
switches itself off automatically (safety shutdown).
Step 2 - Release torch button
Cutting current is interrupted, cutting voltage is switched off.
Post-purge gas flow time (demand-oriented).
If the torch button is pressed once again during the post-purge gas flow time,
no gas pre-flow will occur. Functional sequence is immediately restarted
(quick start).
3.2.4.2
4-step function sequence
Step 1 - Press torch button
Gas pre-flow time 4 seconds.
Pilot arc is ignited.
On contact with work piece, the cutting arc is ignited and the compressed air
is increased to the required throughput rate.
If contact is not made with the work piece within four seconds, the
equipment switches itself off automatically (safety shutdown).
Step 2 - Release torch button
- Prior to ignition of the cutting arc
Equipment switches to the basic setting (safety shut-down).
- After ignition of the cutting arc
Cutting operation is resumed.
If the torch is withdrawn during cutting, the arc is extinguished. This has the
effect of interrupting the cutting current and the equipment shuts down. This
function corresponds to the fourth step.
Step 3 - Press torch button
Cutting operation is resumed.
Step 4 - Release torch button
Cutting current is interrupted, cutting voltage is switched off.
Post-purge gas flow time (demand-oriented).
If the torch button is pressed once again during the post-purge gas flow time,
no gas pre-flow will occur. Functional sequence is immediately restarted
(quick start).
Summary of Contents for BARRACUDA RTC 100
Page 1: ...BARRACUDA RTC 60 100 150 OPERATING INSTRUCTIONS Plasma arc cutting GB...
Page 7: ...Introduction 7 1 2 General Description Fig 1 BARRACUDA...
Page 40: ...Circuit Diagrams 40 9 Circuit diagrams...
Page 41: ...Circuit Diagrams 41...
Page 42: ...Circuit Diagrams 42...
Page 45: ...List of Components 45 1 2 3 6 7 4 8 9 10 11 12 13 14 15 42 16 39 17 20 22 5...
Page 46: ...List of Components 46 38 23 24 25 26 27 60 28 29 30 31 34 E Box 33 35 36 37 32 40 F3 F5...
Page 50: ...Mechanised Interlocks 50 11 4 Connection schematic for A pole mechanised cutting interface...
Page 55: ...by REHM Printed in Germany No 730 1200 06 2013 GB...