![REGULA 7505M Operating Manual Download Page 32](http://html1.mh-extra.com/html/regula/7505m/7505m_operating-manual_1434373032.webp)
32
{
still holding the pinch roller fork, take the protruding end of the magnetic tape
and extract the jammed piece (Figure 11) . If two edges of the magnetic tape
are sticking out – it can be extracted in any direction . In case length of the
tape is less than 200 mm or it is rolled in the tape drive none of magnetic tape
edges will stick out . Thus, the magnetic tape extraction is not possible by the
User and the professional assistance is advised,
{
in case of foreign object remaining in the tract during MT strip removal, it is
recommended to expel a foreign object from the tract with high density paper
strip or a thin cardboard (when the pinch roller fork is manually released) .
It is strictly prohibited to use metal instruments for expelling foreign
objects from the tract!
{
in case a foreign object still remains in, it is recommended to apply to the
manufacturer’s service center .
Replacement of the rubber sleeve gasket of the Combination Magnetic Scanner
(CMS) with rotary concentrator:
{
unscrew 2 screws at the rotary concentrator fork face (Figure 8, pos . 7) and
pull out the concentrator axle (Figure 8, pos . 3),
{
remove the used rubber sleeve gasket and replace it with an auxiliary one
from the Spare Parts and Repair Kit,
{
assemble the unit in the reverse order .
Figure 11
Manual extraction of the magnetic tape from OMB tape drive
Summary of Contents for 7505M
Page 2: ......