REGULA 7505M Operating Manual Download Page 25

25

To  renew  ethyl  alcohol  operative  reserve  –  take  the  container  for  alcohol  from  the  box 

(Figure 7d), remove the cap, unscrew the head and pour about 5 ml of alcohol . Screw the head 

of the container and establish the cap on its place .

2.2.2.3 Intended Use of the Device

Intended use of the device is possible after the requirements given in paragraph 2 .2 .1 are 

observed and the procedures described in paragraph 2 .2 .2 .2 are performed .

Magnetic copying of an object using MCAS consists of the following steps:

 

z

preparation of the investigated surface,

 

z

selecting MT type,

 

z

preparation (demagnetization) of MT,

 

z

magnetic copying .

The User is to select MT type (metal or plastic) and width (1’’ or ½’’) . The following recom

-

mendations should be taken into consideration:

 

z

Plastic MT is considerably less expensive than metal MT. As technical properties of 

both MT types are almost the same, plastic MT can be used in the majority of cases.

 

z

It is recommended 

not to use plastic MT

 in the conditions which worsen the quality 

of  magnetic  copying  and  shortens  MT  lifetime,  e .g .  on  very  rough  surfaces  (severe 

corrosion, premilling), on hot surfaces (when surface temperature e50 ˚C), 

on surfaces with sticky stains that cannot be removed .

 

z

It is recommended to 

use plastic MT

 in the conditions which improve the quality of 

magnetic copying, e .g . for examining the relief and structure of aluminum objects, for 

examining  weak  internal  stresses  in  ferromagnetic  objects,  for  magnetic  copying  in 

narrow openings and in grooves where the only way to avoid MT damage is to use ½’’ 

plastic MT .

Preparation of the Investigated Surface

Rust layer, especially on the heavily corroded surfaces, often is the only remaining 

carrier of information about original numbers.

Preparation (Demagnetization) of MT

Selecting MT Type

 

z

Provide  easy  access  to  investigated  surface:  disconnect  vehicle  shrouds,  cables  and 

vehicle branch pipes blocking the access . Hereinafter the investigated surface means 

both front and rear areas of the vehicle body data carriers, as well as the front of the 

engine number area .

 

z

Clean investigated surface from foreign particles (such as dust, dirt, sand, tar, etc .), 

as well as from lubricants film with a tissue paper or a brush and, if necessary, clean 

it  with  alcohol,  dry  or  remove  a  moisture .  Impurity  slightly  decreases  the  quality  of 

magnetic copying, but results in untimely magnetic tape wear, while the particles adhered 

to the tape will damage the magneto-optical crystal and foul the tape-drive mechanism .

ATTENTION! Do not remove rust from the surface! 

 

z

take  the  Combination  Magnetic  Scanner  (CMS)  out  of  the  compartment  of  MCAS 

(Figure 1, pos . 13),

 

z

choose the used (processed) magnetic tape strip,

 

z

press and hold the demagnetizer drive button (Figure 8, pos . 1), insert the end of the 

magnetic  tape  strip  into  the  demagnetizer  slot  (Figure  8,  pos .  6)  slightly  pushing  it 

forward until its end appears on the opposite side,

 

z

release the demagnetizer drive button (Figure 8, pos . 1), take the threaded end of the 

magnetic tape strip and pull it through the demagnetizer,

 

z

use  the  demagnetized  magnetic  tape  for  a  new  magnetic  copy  or  place  it  into  the 

cartridge for demagnetized MTs (marked with green marker) (Figure 6a, b) .

Summary of Contents for 7505M

Page 1: ...Certified Quality Management System Operating Manual MAGNETO OPTICAL DEVICES for identification and detection of vehicle units numbers falsification REGULA model 7505M 2014...

Page 2: ......

Page 3: ...rts and Repair Kit SPRK 16 2 INTENDED USE 17 2 1 Intended Use of the Device 17 2 1 1 Operating Limitations 17 2 1 2 Preparation of the Device for Operation 17 2 2 Intended Use of the Device Components...

Page 4: ...f documents z z be an OS Windows user z z study techniques of authenticity control of VINs and related vehicle documents and the OM z z pass practical training on the use of equipment supplied z z pas...

Page 5: ...ions In case any VIN changes are detected further investigations can be carried out using a special set of peripheral hardware tools supplied optionally suitable for a case Application Objects of cont...

Page 6: ...PC external mains power supply source converting AC voltage of 220 V 15 10 frequency 50 Hz 1 Hz into DC voltage of PC power supply External PC power supply source converting DC voltage of vehicle on b...

Page 7: ...b Universal handle with a hinge 1 Bag 9b Extension handles 2 Bag 9b Container for alcohol 10 g 1 Bag 7d Brush 1 Bag Marker 1 Bag Accessories bag 1 Body case 1b Carrier bag for accessories 1 Body case...

Page 8: ...of internal stresses in ferromagnetic objects and examination of aluminum objects surface can be performed with an eddy current scanner supplied optionally Magnetic copy is loaded into the USB device...

Page 9: ...utomatic program correction and panoramic shots stitching of MOV images processing comparison of images measurements of linear and angular sizes saving and printing of image files as illustrations to...

Page 10: ...tered number appears as 201935 altered digits are underlined Digit 9 of the original number was altered manually using cold calking of one element crosspiece of digit 9 with the help of bench tools Th...

Page 11: ...ational certification mark Device sealing is made with the help of destructible security labels applied on the Optic Mechanical Block body and on the device chassis Damages of the security label cause...

Page 12: ...size 12 Approximate size of a VIN image file 75 JPG 640x512 1 8 Mb Working time in autonomous mode depends on PC type usually not more than 3 hours from mains power source not less than 8 hours Consu...

Page 13: ...he copy reflects relief and structural inhomogeneity of the material Permanent magnets of the Combination Magnetic Scanner concentrators serve as sources of magnetic stray fields excitation z z Demagn...

Page 14: ...y the use of 15 mm concentrator is more preferable for detailed examination The use of 21 mm concentrator is more preferable for increasing the examined area Compact Magnetic Scanner Figure 10 pos 1 i...

Page 15: ...lays operative and stored information provides conditions for its processing examination and documenting The device can operate both with a stationary PC and with a 12 laptop If the User purchases a 1...

Page 16: ...newing operative reserve of consumables and for servicing during examination Full composition and application z z the cutter is used for cutting magnetic tape from stock to fill up operative MCAS rese...

Page 17: ...prohibited to use the device under rain In case water or condensate appear on device components case device operation must be stopped and can be renewed only after drying z z The device should not be...

Page 18: ...scanner supplied optionally z z Do not use damaged MT having breaks with sharp edges strongly crumpled MT with bent on edges or dirty MT see paragraphs 2 2 2 2 and 3 2 Failure to observe these require...

Page 19: ...number digits shall be visible on the 2nd and 6th digit position z z In case of malfunction at any stage of operation control see paragraphs 3 and 4 Magneto optical visualization of the test object su...

Page 20: ...uffer to the tape receiving magazine or to the bunker to the closest location The green LED MT in the tract is fading indicating that MT stopped moving The red LED MT in the buffer comes on Do not rem...

Page 21: ...2 2 2 Do not use the magnetic tape shorter than 150 mm otherwise in case of tape jamming in the tape path there won t be a possibility of manual tape removal and this case may require the backup of th...

Page 22: ...r the tape along the blade edge Figure 5 pos 2 It is better to twist the tape but not tear it Figure 5b When tearing the MT avoid forming fins on strips edges z z put the obtained magnetic tape strip...

Page 23: ...ng a special container from SPRK Figure 7d MT with considerable bends breaks Figure 7e breaks of edges Figure 7f and punctures cannot be mended Such tapes should not be used in case the fault area can...

Page 24: ...g in USB device for Magneto Optical Visualization MOV and use of polluted and damaged MTs leads to device malfunction As a result of being damaged and worn out plastic MT loses particles of the workin...

Page 25: ...ooves where the only way to avoid MT damage is to use plastic MT Preparation of the Investigated Surface Rust layer especially on the heavily corroded surfaces often is the only remaining carrier of i...

Page 26: ...rd to reach place is shown in Figure 9b z z Make a magnetic copy Lower the concentrator of the magnetic scanner unto the fixed magnetic tape strip and slightly pressing it down move it from the beginn...

Page 27: ...agnetic Scanner with rotary concentrator b Making magnetic copy of a vehicle number platform located in hard to reach place 2 3 4 7 5 6 2 1 CMS 2 magnetic clamp 3 MT strip 4 investigated surface 5 uni...

Page 28: ...10 Making magnetic copy of vehicle number platform using the Compact Magnetic Scanner with longitudinal fixation of the spring clip b Making a magnetic copy of a vehicle number platform using the Com...

Page 29: ...alcohol dosage or the paper density is selected incorrectly cleaning tape can be jammed in the tract In this case it is required to extract the cleaning tape manually as described in paragraph 4 2 It...

Page 30: ...to be carried out whenever the surface becomes polluted Approximate rate of alcohol application 25 g Technical maintenance of the device when putting it for storage pack the components of the device i...

Page 31: ...sleeve gasket as described in paragraph 4 2 No precision when viewing the stitched image Improper preparation of the investigated surface or a thick lacquer and paint coating Improve preparation of t...

Page 32: ...from the tract with high density paper strip or a thin cardboard when the pinch roller fork is manually released It is strictly prohibited to use metal instruments for expelling foreign objects from t...

Page 33: ...erform maintenance works as described in paragraph 3 2 Devices can be stored in stacks up to 5 items high TRANSPORTATION The device can be transported in the industrial packaging of the manufacturer p...

Page 34: ...rmity with mandatory requirements of state standards and current technical documentation Responsible for acceptance Seal _________________ _________________ Signature Full Name _________________ YY MM...

Page 35: ...ical device for identification and detection of vehicle identification numbers falsification Regula 7505 Serial number ___________ is sold to Seal Buyer s Name ______________________ Date of sale ____...

Page 36: ...1 314 Volokha Street Minsk 220036 Republic of Belarus Phone 375 17 286 2825 Fax 375 17 210 2397 e mail mail regula by http www regulaforensics com...

Reviews: