Check  the  device  components  and  prepare  them  for  operation  in  accordance  with 

paragraphs 2 .2 .1–2 .2 .3 .

 

z

Prepare the PC and its peripherals for operation in accordance with the corresponding 

technical description .

In case a PC is purchased by the User (see requirements listed in paragraph 1.2.4), 

the following operations should performed to install the PC correctly:

 

z

Install the OS and necessary programs in conformity with their technical description .

 

z

Install the software (Videoscope/NUCA (EYER), Autodocs) and their drivers following 

the installation guide .

 

z

Install and adjust fixing pins to fix the PC (Figure 1, pos . 5) according to PC sizes and 

its components (disk storages, memory cards, slots and etc .) position .

 

z

Adjust the length of the cable of the USB-device for MOV . The cable must have some 

length reserve which provides its freedom of movement when opening/closing the PC 

folding panel (Figure 1, pos . 4) .

 

z

Stick air-cushions on the inner side of the body-case cover in order to fill in the gap 

between the body-case cover and the PC .  Air-cushions should be stuck opposite the PC 

front corners . The thickness of air-cushions is chosen according to the laptop thickness .

Intended Use of Device Components

USB-device for Magneto-Optical Visualization (MOV) 

2.2.1.1 Operating Limitations

 

z

It  is  possible  to  examine  ferromagnetic  materials  only  (iron,  steel,  cast  iron) .  Non-

ferromagnetic materials (aluminum) are examined with the corresponding eddy-current 

scanner (supplied optionally) .

 

z

Do not use damaged MT (having breaks with sharp edges, strongly crumpled), MT with 

bent on edges or dirty MT (see paragraphs 2 .2 .2 .2 and 3 .2) . Failure to observe these 

requirements may result in discrepancies during MT stitching and MT jamming in МОV .

 

z

Avoid  large  abrasive  particles  (dust,  sand,  scale,  etc .),  oils,  preservatives  and  other 

objects (coins, paper clips, etc .) getting into the OMB tape receiving magazine .

 

z

Do not interfere with MT movement in the OMB tape drive tract . Do not try to extract an 

MT strip manually when it is automatically moving in the OMB tract .

 

z

Do not reinstall the operational system and drivers for the device components without 

emergency .

 

z

Do not change settings of the special software . If it is necessary to reinstall the software, 

follow the instructions given in the corresponding software User’s Guide .

 

z

Do not change the arrangement of USB-cables connecting the device components and 

PC slots . The change in cables arrangement may require drivers reinstallation .

2.2

2.2.1

Do not use MT strips shorter than 150 mm. Otherwise in case of tape jamming 

in the tape path, there won’t be a possibility of manual tape removal. This situation 

may require qualified service.

2.2.1.2 Preparation for Operation

 

z

Connect the PC to an external power supply source . The device can be powered by the 

internal (autonomous) PC battery . In this case power supply cables are not connected .

 

z

Switch  on  the  PC .  Start  the  operating  system  and  launch  special  Videoscope/NUCA 

(EYER)  software .  As  soon  as  the  USB-device  for  MOV  is  connected,  the  yellow  LED 

(Figure 3, pos . 4) comes on . The device is ready to operate .

Switching the device on

Summary of Contents for 7505M

Page 1: ...Certified Quality Management System Operating Manual MAGNETO OPTICAL DEVICES for identification and detection of vehicle units numbers falsification REGULA model 7505M 2014...

Page 2: ......

Page 3: ...rts and Repair Kit SPRK 16 2 INTENDED USE 17 2 1 Intended Use of the Device 17 2 1 1 Operating Limitations 17 2 1 2 Preparation of the Device for Operation 17 2 2 Intended Use of the Device Components...

Page 4: ...f documents z z be an OS Windows user z z study techniques of authenticity control of VINs and related vehicle documents and the OM z z pass practical training on the use of equipment supplied z z pas...

Page 5: ...ions In case any VIN changes are detected further investigations can be carried out using a special set of peripheral hardware tools supplied optionally suitable for a case Application Objects of cont...

Page 6: ...PC external mains power supply source converting AC voltage of 220 V 15 10 frequency 50 Hz 1 Hz into DC voltage of PC power supply External PC power supply source converting DC voltage of vehicle on b...

Page 7: ...b Universal handle with a hinge 1 Bag 9b Extension handles 2 Bag 9b Container for alcohol 10 g 1 Bag 7d Brush 1 Bag Marker 1 Bag Accessories bag 1 Body case 1b Carrier bag for accessories 1 Body case...

Page 8: ...of internal stresses in ferromagnetic objects and examination of aluminum objects surface can be performed with an eddy current scanner supplied optionally Magnetic copy is loaded into the USB device...

Page 9: ...utomatic program correction and panoramic shots stitching of MOV images processing comparison of images measurements of linear and angular sizes saving and printing of image files as illustrations to...

Page 10: ...tered number appears as 201935 altered digits are underlined Digit 9 of the original number was altered manually using cold calking of one element crosspiece of digit 9 with the help of bench tools Th...

Page 11: ...ational certification mark Device sealing is made with the help of destructible security labels applied on the Optic Mechanical Block body and on the device chassis Damages of the security label cause...

Page 12: ...size 12 Approximate size of a VIN image file 75 JPG 640x512 1 8 Mb Working time in autonomous mode depends on PC type usually not more than 3 hours from mains power source not less than 8 hours Consu...

Page 13: ...he copy reflects relief and structural inhomogeneity of the material Permanent magnets of the Combination Magnetic Scanner concentrators serve as sources of magnetic stray fields excitation z z Demagn...

Page 14: ...y the use of 15 mm concentrator is more preferable for detailed examination The use of 21 mm concentrator is more preferable for increasing the examined area Compact Magnetic Scanner Figure 10 pos 1 i...

Page 15: ...lays operative and stored information provides conditions for its processing examination and documenting The device can operate both with a stationary PC and with a 12 laptop If the User purchases a 1...

Page 16: ...newing operative reserve of consumables and for servicing during examination Full composition and application z z the cutter is used for cutting magnetic tape from stock to fill up operative MCAS rese...

Page 17: ...prohibited to use the device under rain In case water or condensate appear on device components case device operation must be stopped and can be renewed only after drying z z The device should not be...

Page 18: ...scanner supplied optionally z z Do not use damaged MT having breaks with sharp edges strongly crumpled MT with bent on edges or dirty MT see paragraphs 2 2 2 2 and 3 2 Failure to observe these require...

Page 19: ...number digits shall be visible on the 2nd and 6th digit position z z In case of malfunction at any stage of operation control see paragraphs 3 and 4 Magneto optical visualization of the test object su...

Page 20: ...uffer to the tape receiving magazine or to the bunker to the closest location The green LED MT in the tract is fading indicating that MT stopped moving The red LED MT in the buffer comes on Do not rem...

Page 21: ...2 2 2 Do not use the magnetic tape shorter than 150 mm otherwise in case of tape jamming in the tape path there won t be a possibility of manual tape removal and this case may require the backup of th...

Page 22: ...r the tape along the blade edge Figure 5 pos 2 It is better to twist the tape but not tear it Figure 5b When tearing the MT avoid forming fins on strips edges z z put the obtained magnetic tape strip...

Page 23: ...ng a special container from SPRK Figure 7d MT with considerable bends breaks Figure 7e breaks of edges Figure 7f and punctures cannot be mended Such tapes should not be used in case the fault area can...

Page 24: ...g in USB device for Magneto Optical Visualization MOV and use of polluted and damaged MTs leads to device malfunction As a result of being damaged and worn out plastic MT loses particles of the workin...

Page 25: ...ooves where the only way to avoid MT damage is to use plastic MT Preparation of the Investigated Surface Rust layer especially on the heavily corroded surfaces often is the only remaining carrier of i...

Page 26: ...rd to reach place is shown in Figure 9b z z Make a magnetic copy Lower the concentrator of the magnetic scanner unto the fixed magnetic tape strip and slightly pressing it down move it from the beginn...

Page 27: ...agnetic Scanner with rotary concentrator b Making magnetic copy of a vehicle number platform located in hard to reach place 2 3 4 7 5 6 2 1 CMS 2 magnetic clamp 3 MT strip 4 investigated surface 5 uni...

Page 28: ...10 Making magnetic copy of vehicle number platform using the Compact Magnetic Scanner with longitudinal fixation of the spring clip b Making a magnetic copy of a vehicle number platform using the Com...

Page 29: ...alcohol dosage or the paper density is selected incorrectly cleaning tape can be jammed in the tract In this case it is required to extract the cleaning tape manually as described in paragraph 4 2 It...

Page 30: ...to be carried out whenever the surface becomes polluted Approximate rate of alcohol application 25 g Technical maintenance of the device when putting it for storage pack the components of the device i...

Page 31: ...sleeve gasket as described in paragraph 4 2 No precision when viewing the stitched image Improper preparation of the investigated surface or a thick lacquer and paint coating Improve preparation of t...

Page 32: ...from the tract with high density paper strip or a thin cardboard when the pinch roller fork is manually released It is strictly prohibited to use metal instruments for expelling foreign objects from t...

Page 33: ...erform maintenance works as described in paragraph 3 2 Devices can be stored in stacks up to 5 items high TRANSPORTATION The device can be transported in the industrial packaging of the manufacturer p...

Page 34: ...rmity with mandatory requirements of state standards and current technical documentation Responsible for acceptance Seal _________________ _________________ Signature Full Name _________________ YY MM...

Page 35: ...ical device for identification and detection of vehicle identification numbers falsification Regula 7505 Serial number ___________ is sold to Seal Buyer s Name ______________________ Date of sale ____...

Page 36: ...1 314 Volokha Street Minsk 220036 Republic of Belarus Phone 375 17 286 2825 Fax 375 17 210 2397 e mail mail regula by http www regulaforensics com...

Reviews: