![REGULA 7505M Operating Manual Download Page 18](http://html1.mh-extra.com/html/regula/7505m/7505m_operating-manual_1434373018.webp)
18
z
Check the device components and prepare them for operation in accordance with
paragraphs 2 .2 .1–2 .2 .3 .
z
Prepare the PC and its peripherals for operation in accordance with the corresponding
technical description .
In case a PC is purchased by the User (see requirements listed in paragraph 1.2.4),
the following operations should performed to install the PC correctly:
z
Install the OS and necessary programs in conformity with their technical description .
z
Install the software (Videoscope/NUCA (EYER), Autodocs) and their drivers following
the installation guide .
z
Install and adjust fixing pins to fix the PC (Figure 1, pos . 5) according to PC sizes and
its components (disk storages, memory cards, slots and etc .) position .
z
Adjust the length of the cable of the USB-device for MOV . The cable must have some
length reserve which provides its freedom of movement when opening/closing the PC
folding panel (Figure 1, pos . 4) .
z
Stick air-cushions on the inner side of the body-case cover in order to fill in the gap
between the body-case cover and the PC . Air-cushions should be stuck opposite the PC
front corners . The thickness of air-cushions is chosen according to the laptop thickness .
Intended Use of Device Components
USB-device for Magneto-Optical Visualization (MOV)
2.2.1.1 Operating Limitations
z
It is possible to examine ferromagnetic materials only (iron, steel, cast iron) . Non-
ferromagnetic materials (aluminum) are examined with the corresponding eddy-current
scanner (supplied optionally) .
z
Do not use damaged MT (having breaks with sharp edges, strongly crumpled), MT with
bent on edges or dirty MT (see paragraphs 2 .2 .2 .2 and 3 .2) . Failure to observe these
requirements may result in discrepancies during MT stitching and MT jamming in МОV .
z
Avoid large abrasive particles (dust, sand, scale, etc .), oils, preservatives and other
objects (coins, paper clips, etc .) getting into the OMB tape receiving magazine .
z
Do not interfere with MT movement in the OMB tape drive tract . Do not try to extract an
MT strip manually when it is automatically moving in the OMB tract .
z
Do not reinstall the operational system and drivers for the device components without
emergency .
z
Do not change settings of the special software . If it is necessary to reinstall the software,
follow the instructions given in the corresponding software User’s Guide .
z
Do not change the arrangement of USB-cables connecting the device components and
PC slots . The change in cables arrangement may require drivers reinstallation .
2.2
2.2.1
Do not use MT strips shorter than 150 mm. Otherwise in case of tape jamming
in the tape path, there won’t be a possibility of manual tape removal. This situation
may require qualified service.
2.2.1.2 Preparation for Operation
z
Connect the PC to an external power supply source . The device can be powered by the
internal (autonomous) PC battery . In this case power supply cables are not connected .
z
Switch on the PC . Start the operating system and launch special Videoscope/NUCA
(EYER) software . As soon as the USB-device for MOV is connected, the yellow LED
(Figure 3, pos . 4) comes on . The device is ready to operate .