Temperature Control Unit 300L(D)/350L(D)
Operating Instructions
•
21
The item numbers of the components can be found in the corresponding
drawings in these operating instructions and the electrical circuit dia-
grams of the temperature control unit.
CAUTION
Only original Regloplas spare parts may be used!
In case of damage from the use of non-original parts, the warranty will be ren-
dered null and void!
Transport
CAUTION
Allow the temperature control unit to cool down; switch off - press the main
switch and disconnect from mains (see chapter on "Switching off the tempera-
ture control unit")!
Disconnect all hose couplings from the temperature control unit!
Before shipping, the temperature control unit must be drained through the
discharge port on the delivery pump (see maintenance section). Because
of the danger of freezing (bursting of the cooling pipes) at low tempera-
tures, the cooler must be blown out as follows:
1) Switch on the temperature control unit - press the main switch
and press the
ON/OFF
button
2) Set the set-point value on the controller to 0 °C
3) Check that the cooler solenoid valve (
Y6
) is open
4) Blow out the cooler with compressed air (max. 6 bar)
5) Switch off the temperature control unit with the
ON/OFF
button,
and then press the main switch and unplug the mains plug
6) Do not tip the temperature control unit - heat transfer medium
remaining in the unit could spill out
7) Use the original packaging and mark the top side clearly
Disposal
The temperature control unit must be drained completely and disposed of
in accordance with local regulations.
The temperature control unit can also be returned to Regloplas AG, Swit-
zerland, for disposal.