V
09/2011
14
•
Operating Instructions
Temperature Control Unit 300L(D)/350L(D)
•
User password - Default
0000
(switched off)
•
Technician password - Default
0100
•
Service password - only for personnel trained by Regloplas
NOTE
It is strongly recommended that an operator password should be set up when
commissioning the temperature control unit.
Operation with Timer
The RT100 control system has an integrated real-time clock. If the
Timer
option is available, the device can be switched on and off with this option.
Alarm Reset and Alarm History
Alarm Reset
If an alarm has been triggered, the signal horn can be switched off by
pressing the
Alarm Reset
button. After the malfunction has been reme-
died, the alarm can be reset by once again pressing the
Alarm Reset
button.
The
Alarm Reset
button also allows manual acknowledgement of the au-
tomatic switchover (toggling) from consumer temperature control
Sn2
to
outlet temperature control
Sn1
if sensor
Sn2
is defective or removed
from the consumer.
Alarm History
If there is no alarm pending, the
Alarm Reset
button can be used to view
the alarm history.
Save/Reset of the Setting Values
The RT100 control system provides the facility to load the factory settings
or user settings at any time in a simple manner. Two different customer-
specific settings can be loaded afresh (user setting 1 and 2).
RT100 Control System - Unlocking Options
The RT100 control system can be equipped with different hardware and
software options.
The software options must be activated with a file via USB stick. This re-
quires the serial number of the control system, which is displayed in the
parameter
Options
and can be seen on the power section by the bar-
code.
The serial number consists of 6 letters (e.g. AALASF).