Regency U31-10 Gas Fireplace Insert
|
15
|
15
installation
LOG SET INSTALLATION
GAS INSERT
908-783a
03/30/09
U31-2 / IG34
Page 1 of 3
LOG SET INSTALLATION
Read the instructions below carefully and refer to the diagrams. If logs are broken do not use the unit until
they are replaced. Broken logs can interfere with the pilot operation.
The gas log kit contains the following:
a)
02-43
Rear Log
b)
02-45
Front Right Log
c)
02-56
Middle Left Log
d)
02-46
Left Top Log
e)
02-47
Center Log
f)
02-48
Middle Right Log
g)
02-44
Front Left Log
h)
902-154
Embers
i)
902-153
Rockwool
j)
902-179/P Vermiculite
k)
946-669
Platinum Embers
(supplied with packaged manual)
Note: Install Optional Brick Panels prior to installing logs.
1)
Carefully remove the logs from the box and unwrap
them. The logs are fragile, handle with care -
do not
force into position.
2)
Sprinkle the vermiculite around the fi rebox base. Take
some of the embers (approx. 1/3 of the bag) and
sprinkle over the vermiculite.
3)
Place Rear Log A)02-43 on the two pins on the rear
log support.
Vermiculite
and embers
Vermiculite
and embers
Vermiculite
and embers
Pins on Rear Log Support
4)
Place Front Right Log B)02-45 on the two pins as
shown.
A)02-43
B)02-45
The "02" refer numbers (i.e. 02-43) are
molded into the rear of each log.