Regency PTO28-1 City Table Outdoor Gas Fireplace

  |     

27

27

warranty

Regency

®

 Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully 

inspects each unit thoroughly before it leaves our facility.  FPI Fireplace Products International Ltd. is pleased to extend this limited warranty to 
the original purchaser of a Regency

®

 Product. This warranty is not transferable.

Limited Warranty:

  

The gas valve, burner tube, pilot assembly, thermocouple, flame sensor, electrode, control modules, switches,wall switches and wiring for battery compartment 
are all covered for two (2) years on parts and one (1) year on subsidized* labor only against defect in manufacture, from date of purchase.

Ceramic logs, volcanic stones, wheels, rubber feet, glass crystals, tempered glass wind shield and glass nickel corners carry a one (1) year warranty against 
manufacturing defect, on parts, with no labor allowance, from date of purchase.

Special finishes such as stainless steel components and powder coated surfaces are not covered against environmental damage including corrosion, 
misuse, cleaning or handling issues that cause discoloration.  To receive consideration any damage claim against stainless steel components or powder 
coated finishes must be submitted at the time of installation.  Damage from abrasive cleaners and discolouration to stainless components caused by heat, 
are not covered under warranty.  Damage reported after installation will not be covered.

Repair/replacement parts purchased by the consumer from FPI after the original coverage has expired on the unit will carry a 90 day warranty, valid only 
with a receipt. Any item shown to be defective will be repaired or replaced at our discretion. No labor coverage is included with these parts.

Conditions:

Any part or parts of this unit which in our judgement shows evidence of such defects will be repaired or replaced at FPI's option, through an accredited 
distributor or agent provided that the defective part be returned to the distributor or agent 

Transportation Prepaid

, if requested.

It is the general practice of FPI to charge for larger, higher priced replacement parts and issue credit once the replaced component has been returned to 
FPI and evaluated for manufacturer defect.

The authorized selling dealer is responsible for all in-field service work carried out on your Regency

®

 product. FPI will not be liable for results or costs of 

workmanship from unauthorized service persons or dealers. 

At all times FPI reserves the right to inspect product, in the field, which is claimed to be defective.

All claims must be submitted to FPI by authorized selling dealers. It is essential that all submitted claims provide all of the necessary information including 
customer name, purchase date, serial #, type of unit, problem, part or parts requested and a copy of the bill of sale/proof of purchase must also accompany 
any submitted claims, without this information the warranty will be invalid.

Exclusions:

Batteries, valve gasketing, paint and minor shade mismatches are not covered under this warranty policy.

At no time will FPI be liable for any consequential damages which exceed the purchase price of the unit. FPI has no obligation to enhance or modify any 
unit once manufactured. ie. as products evolve, field modifications or upgrades will not be performed.

FPI will not be liable for travel costs for service work. 

Installation and environmental problems are not the responsibility of the manufacturer and therefore are not covered under the  terms of this warranty policy.

Any unit which shows signs of neglect or misuse is not covered under the terms of this warranty policy.

The warranty will not extend to any part which has been tampered with or altered in any way, or in our judgment has been subject  to misuse, improper 
installation, negligence or problems caused by environmental or geographical conditions, inadequate ventilation.

It is the responsibility of the home owner to service and maintain the appliance. If any claims are sent to FPI, you may be asked for service records to 
ensure the appliance has been maintained. Retain all receipts for both service and/or parts which may have been replaced. Lack of service/maintenance 
is the largest contributor to malfunction of an appliance and is not covered under the terms of this warranty.

Freight damage to stoves and replacement parts is not covered by warranty and is subject to a claim against the freight carrier by the dealer.

FPI will not be liable for acts of God, or acts of terrorism, which cause malfunction of the appliance.

Malfunction/damage of this appliance due to mother nature (wind, rain, snow, floods, etc.) is not covered under the terms of this warranty policy. Some minor 
expansion, contraction, or movement of certain parts and resulting noise, is normal and not a defect and therefore not covered under this Limited Warranty.
If the appliance has been operated in atmospheres contaminated by chlorine, fluorine, or other damaging chemicals, it will not be covered under this Limited 
Warranty.

Performance problems due to operator error will not be covered by this warranty policy.

Products made or provided by other manufacturers and used in conjunction with the operation of this appliance without prior authorization from FPI, may 
create a danger and  nullify your warranty on this product.

Any alteration to the unit which causes sooting or carboning that results in damage to the interior / exterior facia is not the responsibility of FPI.

Subsidy according to job scale as predetermined by FPI.

Outdoor Products 2015

Summary of Contents for Plateau

Page 1: ...nguish any open flame If odor continues keep away from the appliance and im mediately call your gas supplier or fire department Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department WARNING Improper installation adjustm...

Page 2: ...tive Gas Appliance by REGENCY The City Table Outdoor Decorative Gas Appliance has been designed to provide you with all the warmth and charm of a fire at the flick of a switch The City Table Outdoor Decorative Gas Appliance has been approved by Warnock Hersey Intertek for both safety and efficiency As it also bears our own mark it promises to provide you with economy comfort and security for many ...

Page 3: ...nt 10 Gas Pipe Pressure Testing 10 LP Tank Gas Connection 11 LP hard line conversion for Use in place of LP tank 12 Conversion from LP to NG 14 Table top Installation 16 Glass Crystal Basalt volcanic stones installation 17 Log set installation 18 Optional glass surround Installation 19 City table cover Installation 20 Operating Instructions 21 Lighting Procedure 21 Shutdown Procedure 21 First Fire...

Page 4: ...re d chappement Grandeur de l injecteur D bit Calorifique maximum selon D bit Calorifique minimum selon l altitude é é é é basse é é 14 WC C E 3 49 kPa 5 WC C E 1 25 kPa 3 5 WC C E 0 87 kPa 0 5 WC C E 0 12 kPa 32 DMS 33 500 Btu h 9 82 kW 13 000 Btu h 3 80 kW 0 4500 ft pi 0 1372m Pression d allimentation maximum Pression d allimentation minimum Pression à la tubulure d chappement lev e Pression à l...

Page 5: ...Regency PTO28 1 City Table Outdoor Gas Fireplace 5 5 dimensions UNIT DIMENSIONS CITY TABLE NOTE Optional glass surround shown ...

Page 6: ... NOT BE BURNED IN THIS APPLIANCE DO NOT USE THIS APPLIANCE IF ANY PART HAS BEEN UNDER WATER IMMEDIATELY CALL A QUALIFIED SERVICE TECHNICIAN TO INSPECT THE APPLIANCE AND TO REPLACE ANY PART OFTHE CONTROL SYSTEM AND ANY GAS CONTROL WHICH HAS BEEN SUBMERGED UNDER WATER YOUNG CHILDREN SHOULD BE CARE FULLY SUPERVISED WHENTHEY ARE IN THE SAME AREA AS THE APPLI ANCE TODDLERS YOUNG CHILDREN AND OTHERS MAY...

Page 7: ...ION Any alteration to the product that causessootingorcarboningthatresultsindam ageisnottheresponsibilityofthemanufacturer LOCATING YOUR OUTDOOR DECORATIVE GAS APPLIANCE 1 When selecting a location for your outdoor decorative gas appliance ensure that the clearances are met 2 This appliance must be installed in an open air situation with natural ventilation without stagnant areas where gas leakage...

Page 8: ...ical Wherever possible avoid locating on a flat wall in a tight corner Floor space doesn t count as open area Install to the manual specs for framing and do not insulate unit or enclosure Framing enclosure must at least meet minimum dimensional specs as per the installation manual Only Regency approved media should be used in the firebox i e stones glass Be aware of pressure zones due to location ...

Page 9: ...ES The clearances listed below are Minimum distances unless otherwise stated A major cause of fires is failure to maintain required clearances air space to combustible materials It is of the greatest importance that this decorative gas appliance be installed only in accordance with these instructions PTO28 Clearance Requirements Clearance Dimension Measured From A Back wall 12 305mm Table Top to b...

Page 10: ...ulator to reduce gas flow to appliance PTO28 NG1 SYSTEM DATA Max Supply Pressure 14 WC 3 49 kPa Min Supply Pressure 5 WC 1 25 kPa Manifold Pressure High 3 5 WC 0 87 kPa Manifold Pressure Low 0 5 WC 0 12 kPa Orifice Size 32 DMS Maximum Input 33 500 Btu h 9 82 kW Minimum Input 13 000 Btu h 3 80 kW PTO28 LP1 SYSTEM DATA Max Supply Pressure 14 WC 3 49 kPa Min Supply Pressure 12 WC 2 99 kPa Manifold Pr...

Page 11: ...y bolt to allow LP tank to be seated on the holder seat tank and tighten butterfly bolt LP TANK GAS CONNECTION 4 Check all gas connections under normal operating pressure for leaks with soapy water NOTE If soap bubbles this would indicate a gas leak 5 Reverse step 1 Remove this panel Switch Side Handle Average LP Tank Burn Times High 20lb Tank 13 Hrs Diagram 1 Diagram 2 Tank Holder Butterfly Bolt ...

Page 12: ... tank and LP hose from valve 4 Secure regulator in position with top bracket secure with 2 screws NOTE Top bracket to sit over top of lower bracket Attach supplied MAX 0 5 PSI sticker to top bracket LP hose Regulator Regulator Bracket Top Bracket 3 Install regulator bracket onto unit base with 2 screws Connect flex line to regulator position regulator onto bracket Diagram 2 Diagram 4 Diagram 3 Dia...

Page 13: ...ppliance The connector removed in previous steps can be used on the inlet side of the regulator 8 Check all gas connections at valve regulator and LP outlet under normal operating pressure for leaks with soapy water NOTE If soap bubbles this would indicate a gas leak 9 Check inlet and outlet pressures 10 Reinstall panels 6 Connect flex line to valve fitting Connect flex line to valve Diagram 7 ...

Page 14: ...ONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION Each Kit contains one NG Conversion Kit Conversion Kit Contains Qty Part Description 1 904 688 Burner Orifice 32 1 938 529 Yellow NG label 1 909 265 MAX 0 5 PSI label 1 286 035 Regulator mounting base 1 286 036 Regulator mounting top 1 911 135 Regulator NG 1 904 978 3 8 Flex pipe black 18 length 4 904 959 8 Phillips 1 919 328 Inst...

Page 15: ...ocation to install regulator Access for Hard line Diagram 7 Diagram 8 Diagram 9 9 Remove connector from end of flex line Remove connector Diagram 10 11 Attach the label this unit has been converted to NG near on top of the serial decal 12 Replace red LPG label with yellow NG label 13 Bring gas to appliance The connector removed in previous steps can be used on the inlet side of the regulator 14 Re...

Page 16: ...handling the panels even when removing protective coating Stainless will discolor slightly during normal operation This is normal and should not be considered a defect All hand and finger marks MUST be cleaned off with a soft cloth and a stainless steel cleaner Most stainless steel cleaners leave a film residue on the surface of the panels Use an ammonia based cleaner ie glass cleaner to remove th...

Page 17: ...ny unapproved glass or stones will not be covered under warranty Important Glass crystals must NOT be installed in the shield Shield must remain free and clear When using Basalt Volcanic Stones DO NOT cover the shield and thermocouple area 1 Spread crystals over burner Base and burner tube should not be visible when complete Do not cover thermocouple 3 Basalt Volcanic Stones shown stacked over the...

Page 18: ...position shown below 4 Install Log C over Log A as shown below 5 Install Log D over Log B and Log A as shown below Final Install A B C D Read the instructions below carefully and refer to the images If the logs are broken do not use the unit until they are replaced Broken logs can interfere with pilot operation Improper positioning of the logs may create carbon build up and can alter the unit s pe...

Page 19: ...ip the glass back over and place on a soft surface The glass is now right side up The glass should be raised up 1 2 in bracket as shown below 4b Use supplied spacer tool to determine where the bottom bracket should be placed and secured 4a After the 4 top brackets are installed flip over and place on a soft surface to install the 4 bottom brackets 7 Place assembled glass surround on table top ensu...

Page 20: ...her cover over the glass surround when not in use LEAF COVER 1 Place the leaf cover over the glass crystals when not in use WEATHER COVER 1 Place the weather cover over the entire table when not in use CAUTION Never start the unit with the cover on Let the unit cool before installing the cover Turn off gas supply to unit before installing cover Diagram 1 Diagram 2 Diagram 3 ...

Page 21: ...g this appliance 2 Check to ensure there are no gas leaks 3 Verify log placement If the pilot cannot be seen when lighting the unit the logs have been incorrectly positioned LIGHTING PROCEDURE 1 Remove cover if installed 2 Turn on gas to appliance 3 Using a long lit match or BBQ lighter position ignition source anywhere on the burner tube 4 Turn Gas Control Knob counter clockwise to the ON positio...

Page 22: ...ent clean See installation and operating instructions accompanying appliance WARNING If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to the owner s information manual provided with this appliance For assi...

Page 23: ... floating If there is a problem call a qualified service person 6 The appliance must be inspected before use and at least annually by a qualified field service person to ensure that the flow of combustion and ventilation air is not obstructed 7 Do not use this appliance if the valve and or electronic components have been or are submerged under water Immediately call a qualified service technician ...

Page 24: ...er tray by removing 8 screws in locations shown below in Diagram 2 3 Slide burner away from orifice and remove as shown below in Diagram 3 6 Remove knob by pulling out 7 Remove panel by lifting up and out 8 Remove 2 screws by valve bracket as shown below 10 Replace with new valve assembly 11 Reverse steps 8 1 4 Turn off gas supply and remove flex connection at valve 5 Remove 4 screws to remove val...

Page 25: ... LP 911 135 Regulator NG 3 5 911 136 Regulator NG 10 904 688 Orifice 32 NG 904 641 Orifice 50 LP 5 BBQ LP Tank 7 286 026 G Side Panel Knob Side 286 034 G Side Panel Propane Side with handle 286 027 G Side Panel 4 slots 286 028 G Side Panel no slots 8 286 025 G City Table Leaf Cover Grey 286 037 City Table Leaf Cover Stainless 286 938 Seasonal weather cover 948 054 Rubber legs each 919 326 Manual N...

Page 26: ...ount 5 286 007 Drainage Bracket 6 286 014 Inner burner tray 8 286 010 Burner bracket 9 286 011 Burner bracket 2 10 286 012 Burner bracket 3 14 911 151 Valve Copreci 15 286 017 Valve Bracket Copreci 16 286 016 Valve Holder 17 911 152 Knob 21 286 031 Thermocouple mount 22 911 150 Thermocouple 23 286 032 Burner Bracket 24 286 033 Valve Tray Heat Shield BURNER ASSEMBLY ...

Page 27: ...itted claims provide all of the necessary information including customer name purchase date serial type of unit problem part or parts requested and a copy of the bill of sale proof of purchase must also accompany any submitted claims without this information the warranty will be invalid Exclusions Batteries valve gasketing paint and minor shade mismatches are not covered under this warranty policy...

Page 28: ...ller ____________________________________________________________ Phone ____________________________________________________________ Date Installed _______________________________________________________ Serial No ___________________________________________________________ Register your Regency warranty online www regency fire com Reasons to register your product online today View and modify a lis...

Reviews: