TECHNICAL GUIDE

AFFINITY 

MODELS: PV9

GAS-FIRED
CONDENSING / HIGH EFFICIENCY
DOWNFLOW/HORIZONTAL
TWO STAGE VARIABLE SPEED FURNACES

NATURAL GAS
60 - 120 MBH INPUT

Due to continuous product improvement, 
specifications are subject to change without notice.

Visit us on the web at www.york.com for the most 
up-to-date technical information.

Additional rating information can be found at 
www.gamanet.org.

EFFICIENCY
RATING
CERTIFIED

ISO 9001

Certified Quality

Management System

036-21636-002 Rev. A (1205)

FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

DESCRIPTION

These Category IV, highly efficient, compact, condensing
type furnaces are designed for residential and commercial
installations in a basement, closet, alcove, recreation room or
garage where the ambient temperature is above 32°F, or
higher. They may be either side wall or thru-roof vented using
approved plastic type combustion air and vent piping. All
units are factory assembled, wired and tested to assure
dependable and economical installation and operation.

WARRANTY

Lifetime limited warranty on both heat exchangers to the orig-
inal purchaser; a 20-year limited warranty from original instal-
lation date to subsequent purchaser.

10-year warranty on the heat exchanger in commercial appli-
cations.

5-year limited parts warranty.

FEATURES

• Two stage heating operation includes:

- Two stage gas valve

- Two stage inducer operation

• Provides increased comfort level & very quiet unit opera-

tion

• Adjustable delay timer allows two stage operation with sin-

gle stage thermostat

Compact, easy to install, ideal height 40" cabinet

Blower-off delay for cooling SEER improvement.

Easy to connect power/control wiring.

Built-in, high level self diagnostics with fault code display.

Low unit amp requirement for easy replacement application.

Integrated control module for reliable, economical operation.

May be installed as either two-pipe (sealed combustion) or 
single pipe vent (using indoor combustion air)

Top intake & vent connection allows installation in narrow 
locations.

Electronic Hot Surface Ignition saves fuel cost with increased 
dependability and reliability.

Induced combustion system with inshot main burners for 
quiet, efficient operation.

No special vent termination kit required.

100% shut off main gas valve for extra safety.

24V, 40 VA control transformer and blower relay supplied for 
add-on cooling.

Hi-tech tubular aluminized steel primary heat exchanger.

Secondary (condensing) heat exchanger of 29-4C high-grade 
stainless steel.

Timed on, adjustable off blower capability for maximum com-
fort.

Independent door removal for greater durabilty and ease of 
access.

Easy access from front of unit for cleaning, maintenance or 
service.

Protection from intake, exhaust or condensate blockage.

Insulated blower compartment for quiet operation.

3-way transition facilitates fresh air piping.

ClimaTraK comfort system allows dealer to customize comfort 
settings based on regional location.

Summary of Contents for PV9 Series

Page 1: ...e Two stage inducer operation Provides increased comfort level very quiet unit opera tion Adjustable delay timer allows two stage operation with sin gle stage thermostat Compact easy to install ideal height 40 cabinet Blower off delay for cooling SEER improvement Easy to connect power control wiring Built in high level self diagnostics with fault code display Low unit amp requirement for easy repl...

Page 2: ...HOLE 7 8 29 22 3 4 21 1 4 18 1 2 9 1 8 8 1 2 30 1 8 23 11 16 E FRONT A 40 DIMENSIONS Models Nominal CFM Cabinet Size Cabinet Dimension A in B in C in D in E IN PV9B12N060DH11 1200 B 17 1 2 16 1 4 15 1 3 4 2 3 8 PV9B12N080DH11 1200 B 17 1 2 16 1 4 15 1 3 4 2 3 8 PV9C16N080DH11 1600 C 21 19 3 4 18 1 2 2 1 8 2 3 4 PV9C20N100DH11 2000 C 21 19 3 4 18 1 2 2 1 8 2 3 4 PV9D20N120DH11 2000 D 24 1 2 23 1 4 ...

Page 3: ...4 All filters must be high velocity cleanable type ELECTRICAL AND PERFORMANCE DATA Models Input High Low Output High Low Nominal Airflow Cabinet Width Total Unit AFUE Air Temp Rise MBH MBH CFM In Amps F PV9B12N060DH11 60 39 56 36 1200 17 1 2 9 92 35 65 PV9B12N080DH11 80 52 75 49 1200 17 1 2 9 92 35 65 PV9C16N080DH11 80 52 75 49 1600 21 12 92 35 65 PV9C20N100DH11 100 65 93 61 2000 21 14 92 35 65 PV...

Page 4: ... C A 1287 772 D A 1337 802 C C 1132 668 D C HIGH LOW HEAT CFM WITHOUT FILTERS 60 000 INPUT 3 Ton 80 000 INPUT 3 Ton JUMPER SETTINGS CFM CFM High Low High Low HEAT Tap ADJ Tap 1137 720 1386 962 A Any 974 625 1322 892 B Any 883 593 1250 849 C Any 825 561 1159 768 D Any 80 000 INPUT 4 Ton 100 000 INPUT 5 Ton JUMPER SETTINGS CFM CFM High Low High Low HEAT Tap ADJ Tap 1732 1173 1912 1237 A Any 1631 111...

Page 5: ...of return air openings or return air opening size and add to the ESP from Step 2 to determine the total system static If total system static matches a ESP value in the airflow table i e 0 20 0 60 etc the system airflow corresponds to the intersection of the ESP column and Model Blower Speed row FILTER SIZES Input Output BTU H CFM Cabinet Size Top Return Filter in 60 56 1200 B 2 14 x 20 80 75 1200 ...

Page 6: ...ight O Reversing Valve Energized in Cool TWO STAGE AIR CONDITIONING Comfort Alert Interface HUM Dehumidification Open on Humidity Rise C 24 Volt Common C 24 Volt Common R 24 Volt Hot W2 Second Stage Heat G Fan Y2 Second Stage Cool E W1 First Stage Heat RC 24 Volt Hot Cool XFMR Y1 First Stage Cool R 24 Volt Hot Y Y2 Single Second Stage Cool Y2 Second Stage Cool Y First Stage Cool Y2 Second Stage Co...

Page 7: ...2 Delay on furnace to OFF HM Humidistat BSG Bonnet Sensor Bonnet Sensor Optional BS Bonnet Sensor AUX Auxiliary Heat E W1 First Stage Auxiliary Heat E W1 First Stage Auxiliary Heat W Auxiliary Heat Y2 Second Stage Heat Cool DHM Dehumidistat HUM Dehumidification Open on Humidity Rise Y2 Second Stage Heat Cool Y2 Second Stage Heat Cool Y2 Second Stage Heat Cool Y 2 O Reversing Valve Energized in Coo...

Page 8: ...K0924 24 1 2 Furnace Required in downflow applications when using G FD series coils CONDENSATE NEUTRALIZER KIT 1NK0301 Neutralizer cartidge has a 1 2 plastic tube fittings for installa tion in the drain line Calcium carbonate refill media is also avaiable from the Source 1 Parts p n 026 30228 000 HIGH ALTITUDE PRESSURE SWITCHES For installation where the altitude is less than 8 000 feet it is not ...